Electronic Components Datasheet Search
  English  ▼

X  

LM3533 Datasheet(PDF) 22 Page - Texas Instruments

Click here to check the latest version.
Part # LM3533
Description  Complete Lighting Power Solution for Smartphone Handsets
PDF  63 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI1 [Texas Instruments]
Direct Link  http://www.ti.com
Logo TI1 - Texas Instruments

LM3533 Datasheet(HTML) 22 Page - Texas Instruments

Back Button LM3533 Datasheet HTML 18Page - Texas Instruments LM3533 Datasheet HTML 19Page - Texas Instruments LM3533 Datasheet HTML 20Page - Texas Instruments LM3533 Datasheet HTML 21Page - Texas Instruments LM3533 Datasheet HTML 22Page - Texas Instruments LM3533 Datasheet HTML 23Page - Texas Instruments LM3533 Datasheet HTML 24Page - Texas Instruments LM3533 Datasheet HTML 25Page - Texas Instruments LM3533 Datasheet HTML 26Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 22 / 63 page
background image
LM3533
SNOSC68C – APRIL 2012 – REVISED SEPTEMBER 2015
www.ti.com
Device Functional Modes (continued)
4. If condition 1 or 2 above is satisfied, and the next average period shows no change in the average zone, or
shows a change in the opposite direction, then the criteria in condition 1 or 2 must be satisfied again before
the ALS interface can force a change in the backlight current.
5. The Averager Output (see Figure 27) contains the zone that is determined from the most recent full average
period.
6. The ALS Interface only forces a change in the backlight current at the beginning of an average period.
7. When the ALS forces a change in the backlight current the change is to the brightness target pointed to by
the zone in the Averager Output.
7.4.8.9 Direct ALS Control
In direct ALS control the LM3533 ALS Interface can force the backlight current to either a higher zone target or a
lower zone target using the rules described in ALS Rules. In the example of Figure 30, the plot shows the ALS
voltage, the current average zone which is the zone determined by averaging the ALS voltage in the current
average period, the Averager Output which is the zone determined from the previous full average period, and the
target backlight current that is controlled by the ALS Interface. The following steps detail the Direct ALS
algorithm:
1. When the ALS is enabled the ALS fast start-up (1.1-ms average period) quickly brings the Averager Output
to the correct zone. This takes 3 fast average periods or approximately 3.3ms.
2. The 1st average period the ALS voltage averages to Zone 4.
3. The 2nd average period the ALS voltage averages to Zone 3.
4. The 3rd average period the ALS voltage averages to Zone 0 and the Averager Output shows a change from
Zone 4 to Zone 3.
5. The 4th average period the ALS voltage averages to Zone 2 and the Averager Output remains at its changed
state of Zone 3.
6. The 5th average period the ALS voltage averages to Zone 1. The Averager Output shows a change from
Zone 3 to Zone 2. Because this is the 3rd average period that the Averager Output has shown a change in
the decreasing direction from the initial Zone 4, the backlight current is forced to change to the current
Averager Output (Zone 2's) target current.
7. The 6th average period the ALS voltage averages to Zone 2. The Averager Output changes from Zone 2 to
Zone 1. Because this is in the same direction as the previous change, the backlight current is forced to
change to the current Averager Output (Zone 1's) target current.
8. The 7th average period the ALS voltage averages to Zone 3. The Averager Output changes from Zone 1 to
Zone 2. Because this change is in the opposite direction from the previous change, the backlight current
remains at Zone 1's target.
9. The 8th average period the ALS voltage averages to Zone 3. The Averager Output changes from Zone 2 to
Zone 3.
10. The 9th average period the ALS voltage averages to Zone 3. The Averager Output remains at Zone 3.
Because this is the 3rd average period that the Averager Output has shown a change in the increasing
direction from the initial Zone 1, the backlight current is forced to change to the current Averager Output
(Zone 3's) target current.
11. The 10th average period the ALS voltage averages to Zone 4. The Averager Output remains at Zone 3.
12. The 11th average period the ALS voltage averages to Zone 4. The Averager Output changes to Zone 4.
13. The 12th average period the ALS voltage averages to Zone 4. The Averager Output remains at Zone 4.
14. The 13th average period the ALS voltage averages to Zone 4. The Averager Output remains at Zone 4.
Because this is the 3rd average period that the Averager Output has shown a change in the increasing
direction from the initial Zone 3, the backlight current is forced to change to the current Averager Output
(Zone 4's) target current.
22
Submit Documentation Feedback
Copyright © 2012–2015, Texas Instruments Incorporated
Product Folder Links: LM3533



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com