| Electronic Components Datasheet Search |
|
LM3533 Datasheet(PDF) 30 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
LM3533 Datasheet(HTML) 30 Page - Texas Instruments |
|
30 / 63 page ![]() LM3533 SNOSC68C – APRIL 2012 – REVISED SEPTEMBER 2015 www.ti.com Device Functional Modes (continued) • Read back bits[0] of register 0xB1. 1 = HVLED1 open • Disable all banks (Register 0x27 = 0x00) • Repeat the procedure for the HVLED2 string 7.4.10.3 Open LED (LVLED) The LM3533 features an open LED fault flag indicating one or more of the active LVLED strings are open. An open in an LVLED string is flagged if the voltage at the input to any active low-voltage current sink goes below 110 mV. Because the open LED detect is flagged when any active current sink input falls below 110 mV, certain configurations can result in falsely triggering an open. These include: 1. LED anode tied to CPOUT, charge pump in 1× gain, and VIN drops low enough to bring any active LVLED current sink below 110 mV. 2. LED anode not tied to CPOUT and VLED_ANODE goes low enough to bring any active LVLED current sink below 110 mV. The following list describes a test procedure that can be used in detecting an open in the LVLED strings: • Apply power to the LM3533 • Enable Open Fault (Register 0xB2, bit [0] = 1) • Configure all LVLED strings for Anode connected to CPOUT (register 0x25 bits[6:2] = 1) • Force the Charge Pump into 2× gain (Register 0x26 Bits[2:1] = 11). Ensure that CPOUT and CP are in the circuit and that (VCPOUT is > VFLVLED + VHR_LV) • Set Bank C full-scale Current to 20.2 mA (Register 0x21 = 0x13) • Set Bank C brightness to max (Register 0x42 = 0xFF) • Set the startup ramp times to the fastest setting (Register 0x12 = 0x00) • Assign LVLED1 - LVLED5 to Bank C (Register 0x11 = 0x00, Register 0x10 = 0x00) • Enable Bank C (Register 0x27 Bit[2] = 1 • Wait 4ms • Read back bits[6:2] of register 0xB0. 1 indicates an open and a 0 indicates normal operation (see Table 45). • Disable all banks (Register 0x27 = 0x00) 7.4.10.4 Shorted LED (LVLED) The LM3533 features an LED short fault flag indicating when any active low-voltage LED is shorted (anode to cathode). A short in an LVLED is determined when the LED voltage (VCPOUT – VHR) falls below 1 V. A procedure for determining a short in an LVLED string is: • Apply Power • Enable Short Fault (Register 0xB2, bit [1] = 1) • Enable Feedback on the LVLED Current Sinks (Register 0x25 = 0xFF) • Set Bank C full-scale current to 20.2 mA (Register 0x21 = 0x13) • Set Bank C brightness to max (Register 0x42 = 0xFF) • Set the startup ramp times to the fastest setting (Register 0x12 = 0x00) • Assign LVLED1 to LVLED5 to Bank C (Register 0x11 = 0x00, Register 0x10 = 0x00) • Set Charge Pump to 1× gain (Register 0x26 = 0x40) • Enable Bank C (Register 0x27 Bit[2] = 1 • Wait 4ms • Read bits[6:2] from register 0xB1. A 1 indicates short, and a 0 indicates normal (see Table 46). • Disable all banks (Register 0x27 = 0x00) 30 Submit Documentation Feedback Copyright © 2012–2015, Texas Instruments Incorporated Product Folder Links: LM3533 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |