Back Button LM3533 Datasheet HTML 25Page - Texas Instruments LM3533 Datasheet HTML 26Page - Texas Instruments LM3533 Datasheet HTML 27Page - Texas Instruments LM3533 Datasheet HTML 28Page - Texas Instruments LM3533 Datasheet HTML 29Page - Texas Instruments LM3533 Datasheet HTML 30Page - Texas Instruments LM3533 Datasheet HTML 31Page - Texas Instruments LM3533 Datasheet HTML 32Page - Texas Instruments LM3533 Datasheet HTML 33Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 29 / 63 page
background image
LM3533
www.ti.com
SNOSC68C – APRIL 2012 – REVISED SEPTEMBER 2015
Device Functional Modes (continued)
For low-voltage control banks that do not have their pattern generator enabled, ALS current control is done via
the ALS Mappers. Once a pattern generator is enabled, that particular Control Bank then uses the pattern
scalers for ALS Current Control.
7.4.9.9 Interrupt Output Mode
When INT Mode is enabled (ALS Zone Information Register Bit [0] = 1), INT pin is configured as an interrupt
output. INT is an open-drain output with an active pulldown of typically 66
Ω. In INT Mode the INT output pulls
low if the ALS interface is enabled, and the ALS input has changed zones. Reading back the ALS Zone
Information while in this mode clears the INT output and reset it to its open-drain state.
7.4.10 Fault Flags/Protection Features
The LM3533 contains both an LED open and LED short fault detection. These fault detections are designed to
be used in production level testing and not normal operation. For the fault flags to operate, they must be enabled
via the LED Fault Enable Register (see Table 47).
7.4.10.1 Open LED String (HVLED)
An open LED string is detected when the voltage at the input to any active high-voltage current sink has fallen
below 200 mV, and the boost output voltage has hit the OVP threshold. This test assumes that the HVLED string
that is being detected for an open is connected to the LM3533 boost output (COUT+) (see Table 13). For an
HVLED string not connected to the LM3533 boost output voltage, but connected to another voltage source, the
boost output will not trigger the OVP flag. In this case an open LED string is not detected.
The procedure for detecting an open fault in the HVLED current sinks (provided they are connected to the boost
output voltage) is:
•
Apply power to the LM3533
•
Enable Open Fault (Register 0xB2, bit [0] = 1)
•
Configure HVLED1 and HVLED2 for LED string anode connected to COUT (Register 0x25, bits[1:0] = (1,1)
•
Set Bank A full-scale current to 20.2 mA (Register 0x1F = 0x13)
•
Set Bank A brightness to max (Register 0x40 = 0xFF)
•
Set the startup ramp times to the fastest setting (Register 0x12 = 0x00)
•
Assign HVLED1 and HVLED2 to Bank A (Register 0x10, Bits [1:0] = (0, 0)
•
Enable Bank A (Register 0x27 Bit[0] = 1
•
Wait 4ms
•
Read back bits[1:0] of register 0xB0. Bit [0] = 1 (HVLED1 open). Bit [1] = 1 (HVLED2 open)
•
Disable all banks (Register 0x27 = 0x00)
7.4.10.2 Shorted LED String (HVLED)
The LM3533 features an LED short fault flag indicating one or more of the HVLED strings have experienced a
short. The method for detecting a shorted HVLED strings is if the current sink is enabled and the string voltage
(VOUT – VHVLED1/2) falls to below (VIN – 1 V). This test must be performed on one HVLED string at a time.
Performing the test with both current sinks enabled can result in a faulty reading if one of the strings is shorted
and the other is not.
The procedure for detecting a short in an HVLED string is:
•
Apply power to the LM3533
•
Enable Short Fault (Register 0xB2, bit [1] = 1)
•
Enable Feedback on the HVLED Current Sinks (Register 0x25 = 0xFF)
•
Set Bank A full-scale current to 20.2 mA (Register 0x1F = 0x13)
•
Set Bank A brightness to max (Register 0x40 = 0xFF)
•
Set the startup ramp times to the fastest setting (Register 0x12 = 0x00)
•
Assign HVLED1 to Bank A (Register 0x10, Bits [1:0] = (1, 0)
•
Enable Bank A (Register 0x27 Bit[0] = 1
•
Wait 4 ms
Copyright © 2012–2015, Texas Instruments Incorporated
Submit Documentation Feedback
29
Product Folder Links: LM3533



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com