| Electronic Components Datasheet Search |
|
LM3533 Datasheet(PDF) 16 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
LM3533 Datasheet(HTML) 16 Page - Texas Instruments |
|
16 / 63 page ![]() 0 32 64 96 128 160 192 224 256 Code (D) 21 18 15 12 9 6 3 0 Linear Mapping Exponential Mapping Code x DPWM x 255 1 I I FULLSCALE LED LED x = _ - 46.6 ¨ © § ¸ ¹ · 5 . 5 +1 Code » ¼ º PWM x D x = _ FULLSCALE LED LED I I 862 . 0 « ¬ ª LM3533 SNOSC68C – APRIL 2012 – REVISED SEPTEMBER 2015 www.ti.com Device Functional Modes (continued) 7.4.3.1 Exponential Mapping In Exponential Mapping mode the brightness code to backlight current transfer function is given by Equation 1: where • ILED_FULLSCALE is the full-scale LED current setting (see Table 11) • Code is the backlight code in the Brightness register • DPWM is the PWM input duty cycle. (1) In Exponential Mapping mode the current ramp (either up or down) appears to the human eye as a more uniform transition then the linear ramp. This is due to the logarithmic response of the eye. 7.4.3.2 Linear Mapping In Linear Mapping Mode the brightness code to backlight current has a linear relationship and follows Equation 2: where • ILED_FULLSCALE is the full-scale LED current setting • Code is the backlight code in the Brightness register • DPWM is the PWM input duty cycle. (2) Figure 24. LED Current Mapping Modes 7.4.4 LED Current Ramping 7.4.4.1 Start-Up/Shutdown Ramp The startup and shutdown ramp times are independently programmable in the Start-Up/Shutdown Transition Time Register (see Table 4). There are 8 different start-up and 8 different shutdown times. The start-up times can be programmed independently from the shutdown times, but teach Control bank is not independently programmable. For example, programming a start-up or shutdown time does not affect the already pre- programmed ramp time for each Control Bank. The start-up ramp time is from when the Control Bank is enabled to when the LED current reaches its initial set point. The shutdown ramp time is from when the Control Bank is disabled to when the LED current reaches 0. 16 Submit Documentation Feedback Copyright © 2012–2015, Texas Instruments Incorporated Product Folder Links: LM3533 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |