Back Button ADP5053 Datasheet HTML 16Page - Analog Devices ADP5053 Datasheet HTML 17Page - Analog Devices ADP5053 Datasheet HTML 18Page - Analog Devices ADP5053 Datasheet HTML 19Page - Analog Devices ADP5053 Datasheet HTML 20Page - Analog Devices ADP5053 Datasheet HTML 21Page - Analog Devices ADP5053 Datasheet HTML 22Page - Analog Devices ADP5053 Datasheet HTML 23Page - Analog Devices ADP5053 Datasheet HTML 24Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 20 / 28 page
background image
Rev 21 Jan 2014 15:09 | Page 20
Figure 21. Switching Frequency vs. RT Resistor
There is a frequency-halved bit (FREQ1 and FREQ3 in Register 7) for Channel 1 and Channel 3,
respectively. Each bit can be used to program its switching frequency to be half that of the master
switching frequency, which is set by the RT pin.
When the switching frequency is changed, the values of inductors, the output capacitors, and the
compensation networks must, likewise, be recalculated and changed for stable operation. Refer to the
ADP5051/ADP5053 data sheet for more details on external components selection.
Changing the Peak Current-Limit Threshold in Channel 1/Channel 2
The peak current limit of the ADP5051/ADP5053 evaluation board in Channel 1 and Channel 2 is set to
6.4 A. To change the peak current limit threshold, replace the R8 resistor for Channel 1 (R7 for
Channel 2) with a different value, as shown in Table 5. The programmable current-limit threshold
feature allows for the use of a small size inductor for low current applications.
Table 5. Load Capability Setting on Channel 1
R
ILIM1/RILIM2
I
OUT in Channel 1/Channel 2
Floating
2.5 A, with 4.4 A typical peak current limit
47 kΩ
1.2 A, with 2.6 A typical peak current limit
22 kΩ
4.0 A, with 6.4 A typical peak current limit
Changing the Soft Start Time
The soft start time of the ADP5051/ADP5053 on the evaluation board is programmed at 2 ms for the
four buck regulators. To change the soft start time, replace the R39 and R16 resistors for Channel 1
and Channel 2 (R40 and R18 for Channel 3 and Channel 4) with a different value, as shown in Table 6
(note that N/A means not applicable).
Table 6. Softstart Time Configuration by SS12/SS34 Pins



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com