| Electronic Components Datasheet Search |
|
DLP470TP Datasheet(PDF) 10 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
DLP470TP Datasheet(HTML) 10 Page - Texas Instruments |
|
10 / 48 page ![]() 10 DLP470TP DLPS105A – JANUARY 2018 – REVISED MAY 2018 www.ti.com Product Folder Links: DLP470TP Submit Documentation Feedback Copyright © 2018, Texas Instruments Incorporated (1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device is not implied at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure above or below the Recommended Operating Conditions for extended periods of time may affect device reliability. (2) All voltages are referenced to the common ground VSS. Correct DMD operation requires VBIAS, VCC, VOFFSET, and VRESET power supplies . VSS must also be connected. (3) VOFFSET supply transients must be within specified voltages. (4) Exceeding the recommended allowable voltage difference between VBIAS and VOFFSET may result in excessive current draw. (5) Exceeding the recommended allowable voltage difference between VBIAS and VRESET may result in excessive current draw. (6) This maximum LVDS input voltage rating applies when each input of a differential pair is at the same voltage potential. (7) LVDS differential inputs must not exceed the specified limit or damage may result to the internal termination resistors. (8) The highest temperature of the active array (as calculated using Micromirror Array Temperature Calculation) or of any point along the window edge is defined in Figure 10. The highest window edge temperature is measured using the locations of thermal test points TP2, TP3, TP4, and TP5 in Figure 10. If a particular application causes another point on the window edge to be at a higher temperature, use that point. (9) Temperature delta is the largest difference between the ceramic test point 1 (TP1) and anywhere on the window edge as shown in Figure 10. The window test points TP2, TP3, TP4, and TP5 shown in Figure 10 typically result in the worst case delta. If a particular application causes another point on the window edge to result in a larger delta temperature, that point should be used. 6 Specifications 6.1 Absolute Maximum Ratings Over operating free-air temperature range (unless otherwise noted) (1) MIN MAX UNIT SUPPLY VOLTAGES VCC Supply voltage for LVCMOS core logic(2) –0.5 2.3 V VOFFSET Supply voltage for HVCMOS and micromirror electrode(2)(3) –0.5 11 V VBIAS Supply voltage for micromirror electrode(2) –0.5 19 V VRESET Supply voltage for micromirror electrode(2) –15 –0.3 V |VBIAS – VOFFSET| Supply voltage difference (absolute value)(4) 11 V |VBIAS – VRESET| Supply voltage difference (absolute value)(5) 34 V INPUT VOLTAGES Input voltage for all other LVCMOS input pins(2) –0.5 VCC + 0.5 V |VID| Input differential voltage (absolute value)(6) 500 mV IID Input differential current(7) 6.3 mA CLOCKS ƒCLOCK Clock frequency for LVDS interface, DCLK_A 400 MHz ƒCLOCK Clock frequency for LVDS interface, DCLK_B 400 MHz ƒCLOCK Clock frequency for LVDS interface, DCLK_C 400 MHz ƒCLOCK Clock frequency for LVDS interface, DCLK_D 400 MHz ENVIRONMENTAL TARRAY and TWINDOW Temperature, operating(8) –20 90 °C Temperature, non–operating(8) –40 90 °C |TDELTA| Absolute temperature delta between any point on the window edge and the ceramic test point TP1(9) 30 °C TDP Dew point temperature, operating and non–operating (noncondensing) 81 °C (1) The average temperature over time (including storage and operating temperatures) that the device is not in the elevated dew point temperature range. (2) Exposure to dew point temperatures in the elevated range during storage and operation should be limited to less than a total cumulative time of CTELR. 6.2 Storage Conditions Applicable to the DMD as a component or non-operating in a system MIN MAX UNIT TDMD DMD storage temperature –40 85 °C TDP-AVG Average dew point temperature, non-condensing (1) 24 °C TDP-ELR Elevated dew point temperature range, non-condensing (2) 28 36 °C |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |