Electronic Components Datasheet Search
  English  ▼

X  

ADF5610 Datasheet(PDF) 24 Page - Analog Devices

Part # ADF5610
Description  Microwave Wideband Synthesizer Integrated VCO
PDF  51 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  AD [Analog Devices]
Direct Link  http://www.analog.com
Logo AD - Analog Devices

ADF5610 Datasheet(HTML) 24 Page - Analog Devices

Back Button ADF5610 Datasheet HTML 20Page - Analog Devices ADF5610 Datasheet HTML 21Page - Analog Devices ADF5610 Datasheet HTML 22Page - Analog Devices ADF5610 Datasheet HTML 23Page - Analog Devices ADF5610 Datasheet HTML 24Page - Analog Devices ADF5610 Datasheet HTML 25Page - Analog Devices ADF5610 Datasheet HTML 26Page - Analog Devices ADF5610 Datasheet HTML 27Page - Analog Devices ADF5610 Datasheet HTML 28Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 24 / 51 page
background image
ADF5610
Data Sheet
Rev. 0 | Page 24 of 51
Table 35), written to the VCO subsystem via Register 0x05 =
000000001 0000 VCO_ID, where VCO_ID = 000b.
When autocalibration is enabled (Register 0x0A, Bit 11 = 0),
and a new frequency is written, autocalibration runs. The VCO
frequency error relative to the command frequency is measured
and the results are written to Register 0x11, Bits[19:0], where
Register 0x11, Bit 19 is the sign bit. The result is written in
terms of VCO count error (see Equation 4 through Equation 6).
Using generic values as an example, if the expected frequency at
the RFOUT pin is 7.0 GHz, the PFD frequency is 50 MHz, and
Register 0x0A, Bits[2:0] = 8 (n = 8), expect to measure
3500/(50/28) = 17,920 counts. Frequencies less than 8.0 GHz
route the fundamental frequency directly to the N counter.
Therefore, in this case, 3500 MHz is routed to the N counter.
For RFOUT frequencies greater than or equal to 8.0 GHz, the
internal prescaler of the PLL (Register 0x08, Bit 19) must be
enabled. If a difference of −5 counts is measured in Register 0x11,
that means 17,915 counts were actually measured. With a 7 GHz
VCO, 50 MHz reference, and n = 8, one count is 195.3125 kHz.
Therefore, the actual frequency of the VCO is low in frequency by
5 × 195.3 kHz for a fundamental frequency of 3499.0234375 MHz
or a push/push frequency of 6998.04687 MHz at RFOUT.
PLL SUBSYSTEM
Charge Pump (CP) and Phase Detector (PD)
The PD has two inputs, one from the reference path divider and
one from the RF path divider. When in lock, these two inputs
are at the same average frequency and are fixed at a constant
average phase offset with respect to each other. The frequency
of operation of the phase detector is fPD. Most formulas related
to step size, Δ-Σ modulation, and timers, are functions of the
operating frequency of the phase detector (fPD). The fPD is also
referred to as the comparison frequency of the phase detector.
The phase detector compares the phase of the RF path signal
with that of the reference path signal and controls the charge
pump output current as a linear function of the phase difference
between the two signals. The output current varies linearly over
a full ±2π radians (±360°) of input phase difference.
Charge Pump
A simplified diagram of the charge pump is shown in Figure 24.
The charge pump consists of four programmable current sources.
There are two sources controlling the charge pump gain (up gain,
Register 0x09, Bits[13:7], and down gain, Register 0x09, Bits[6:0])
and two sources controlling the charge pump offset, where the
magnitude of the offset is set by Register 0x09, Bits[20:14] and
the direction is selected by Register 0x09, Bit 21 = 1 for up offset
and Register 0x09, Bit 22 = 1 for down offset.
Charge pump gain is used at all times, whereas charge pump
offset is recommended for fractional mode only. Typically, the
charge pump up and charge pump down gain settings are set to
the same value (Register 0x09, Bits[13:7] = Register 0x09, Bits[6:0])
to minimize spurs.
Charge Pump Gain
Charge pump up and charge pump down gains are set by
Register 0x09, Bits[13:7] and Register 0x09, Bits[6:0], respectively.
The current gain of the pump in amps per radian is equal to the
gain setting of this register (Register 0x09) divided by 2π.
The typical CP gain setting is set from 2 mA to 2.5 mA.
However, lower values can also be used. Note that values less
than 1 mA may result in degraded phase noise performance.
For example, if both Register 0x09, Bits[13:7] and Register 0x09,
Bits[6:0] are set to 50 decimal, the output current of each pump
is 1 mA, and the phase frequency detector gain is kP = 1 mA/2π
radians, or 159 μA/rad. See the Charge Pump (CP) and Phase
Detector (PD) section for more information. Setting both the
charge pump up (Register 0x09, Bits[13:7] = 0) and charge pump
down (Register 0x09, Bits[6:0] = 0) tristates the charge pump.
Tristating can also be achieved using Register 0x0B. Refer to the
Phase Detector Functions section for more information.
Charge Pump Phase Offset
In integer mode, the phase detector operates with zero offset.
The divided reference signal and the divided VCO signal arrive
at the phase detector inputs at the same time. Integer mode does
not require any CP offset current. When operating in integer
mode, disable the CP offset in both directions (up and down)
by writing Register 0x09, Bits[22:21] = 00b, and set the CP offset
magnitude to zero by writing Register 0x09, Bits[20:14] = 0 decimal.
In fractional mode, CP linearity is of paramount importance.
Any nonlinearity degrades phase noise and spurious performance.
These nonlinearities are eliminated by operating the PD with an
average phase offset, either positive or negative (either the
reference or the VCO edge always leads or arrives at the PD).
A programmable CP offset current source adds dc current to
the loop filter and creates the desired phase offset. Positive
current causes the VCO to lead, whereas negative current
causes the reference to lead. Applications requiring an active
loop filter use the up offset, or positive offset. The ADF5610
uses a passive loop filter. Therefore, a down offset, or negative
offset, is recommended. Note that there can be conditions
where the offset that is not typically recommended may provide
improved spurious suppression, but these are often over very
narrow bandwidths.
The CP offset is controlled via Register 0x09. Increasing the
offset current causes the phase offset to scale from 0° to 360°.
The specific level of the charge pump offset current (Register 0x09,
Bits[20:14]) is calculated using Equation 9 and shown in Figure 23.
Required CP Offset = min ((4.3 × 10−9 × fPD × ICP), 0.25 × ICP) (9)
where:
fPD is the comparison frequency of the phase detector (Hz).
ICP is the full-scale current setting (A) of the switching charge
pump (set in Register 0x09, Bits[6:0] and Register 0x09,
Bits[13:7]).



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com