27 / 51 page ![]() Data Sheet ADF5610 Rev. 0 | Page 27 of 51 Lock Detect The lock detect (LD) function verifies that the ADF5610 is generating the desired frequency. LD is enabled by writing Register 0x07, Bit 3 = 1. The ADF5610 provides an LD indicator in the following two ways: • As an output available on the SDO pin of the ADF5610 (configuration is required to use the SDO pin for LD purposes). For more information, see the Configuring the SDO Pin for LD Output section. • Reading from Register 0x12, Bit 1, where Bit 1 = 1 indicates a locked condition and Bit 1 = 0 indicates an unlocked condition. The LD circuit expects the divided VCO edge and the divided reference edge to appear at the PD within a user specified time period (window), repeatedly. Either signal may arrive first. Only the difference in arrival times is significant. The arrival of the two edges within the designated window increments an internal counter. When the count reaches and exceeds a user specified value (Register 0x07, Bits[2:0]), the ADF5610 declares lock. Failure in registering the two edges in any one window resets the counter and immediately declares an unlocked condition. Lock is deemed to be reestablished when the counter reaches the user specified value (Register 0x07, Bits[2:0]) again. The ADF5610 supports the following two lock detect modes: • Analog LD supports a fixed window size of 10 ns. Analog LD mode is selected by writing Register 0x07, Bit 6 = 0. • Digital LD supports a user configurable window size, programmed in Register 0x07, Bits[11:7]. Digital LD is selected by writing Register 0x07, Bit 6 = 1. Lock Detect Configuration Optimal spectral performance in fractional mode requires CP current and CP offset current configuration, described in detail in the Charge Pump (CP) and Phase Detector (PD) section. The PD frequency and settings in the CP (Register 0x09) impact the required LD window size in fractional mode of operation. To function properly, the required lock detect window size is provided by Equation 10 in fractional mode and Equation 11 in integer mode. ( ) _ 9 (A) 1 2.66 10 (sec) (Hz) (A) (Hz) 2 sec CP OFFSET PD CP PD L I D Wi w f d I n f o − +× + × = (10) PD f Window LD × = 2 1 (sec) (11) where: fPD is the comparison frequency of the phase detector. ICP_OFFSET is the charge pump offset current (Register 0x09, Bits[20:14]). ICP is the full-scale current setting of the switching charge pump (Register 0x09, Bits[6:0] or Register 0x09, Bits[13:7]). If the result provided by Equation 10 is equal to 10 ns, analog LD can be used (Register 0x07, Bit 6 = 0). Otherwise, digital LD is necessary (Register 0x07, Bit 6 = 1). Table 11 lists the required Register 0x07 settings to appropriately program the digital LD window size. From Table 11, select the closest value in the digital LD window size columns to the ones calculated in Equation 10 and Equation 11, and program Register 0x07, Bits[11:10] and Register 0x07, Bits[9:7] accordingly. Digital Window Configuration Example For this example, assume the device is in fractional mode, with a 50 MHz PD and the following conditions: • Charge pump gain of 2 mA (Register 0x09, Bits[13:7] = 0x64, Register 0x09, Bits[6:0] = 0x64) • Up offset (Register 0x09, Bits[22:21] = 01b) • Offset current magnitude of 400 μA (Register 0x09, Bits[20:14] = 0x50) Apply Equation 10 to calculate the required LD window size. LD Window (sec) = 3 9 63 6 0.4 10 (A) 1 2.66 10 (sec) 50 10 (Hz) 2 10 (A) 50 10 (Hz) 2 13.33 ns − − − × +× + × ×× × = Locate the Table 11 value that is closest to this result, which is, in this case, 13.3 ≈ 13.33. To set the digital LD window size, program Register 0x07, Bits[11:10] = 10b and Register 0x07, Bits[9:7] = 010b, according to Table 11. For a given operating point, there is typically a correct solution for the lock detect window. However, one solution does not fit all operating points. As observed from Equation 10 and Equation 11, if the charge pump offset or PD frequency is changed significantly, the lock detect window may need to be adjusted. Table 11. Typical Digital Lock Detect Window for Various LD Timer Divide Settings, Register 0x07, Bits[9:7] LD Timer Speed, Register 0x07, Bits[11:10] Digital Lock Detect Window Size Nominal Value (ns) 000 001 010 011 100 101 110 111 00 (Fastest) 6.5 8 11 17 29 53 100 195 01 7 8.9 12.8 21 36 68 130 255 10 7.1 9.2 13.3 22 38 72 138 272 11 (Slowest) 7.6 10.2 15.4 26 47 88 172 338 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |