30 / 59 page ![]() ADMV4530 Data Sheet Rev. A | Page 30 of 59 CHARGE PUMP CURRENT SETUP For a specifically designed loop filter, set the ICP by adjusting the CP_CURRENT value in Bits[7:4], Register 0x01E. Calculate ICP by using the following the equation: ICP = (CP_CURRENT + 1) × 350 µA where CP_CURRENT is an integer value (0 to 15). The default value for a 100 MHz fPFD for CP_CURRENT = 11, which yields a current of 4.2 mA. The applicable range is 0.35 mA to 5.6 mA, with 0.35 mA steps. To change the fPFD, if no change has been made to the existing loop filter components, it is recommended to scale ICP by using the following equation: CP (DEFAULT) PFD (DEFAULT) CP (NEW) PFD (NEW) If I f × = where: ICP (NEW) is the new desired ICP. ICP (DEFAULT) is the default ICP. fPFD (DEFAULT) is the default fPFD. fPFD (NEW) is the new desired fPFD. When ICP(NEW) is obtained, the CP_CURRENT value in Bits[7:4], Register 0x01E, can be updated by using the following rounding function: CP_CURRENT = ROUND 350 μA CP (NEW) I − 1 where ROUND is the mathematical round function. BLEED CURRENT (CP_BLEED) SETUP The charge pump includes a binary scaled bleed current (IBLEED) that is set by using the CP_BLEED value in Register 0x026. The bleed current introduces a slight phase offset in the phase frequency detector to improve integer boundary spurs and phase noise when operating in fractional-N mode. To enable the bleed current for fractional-N mode, set CP_BLEED_EN = 1 (Register 0x027, Bit 3). For integer mode, CP_BLEED_EN must be set to 0. Generally, the optimum bleed current value is 115 (431.25 µA), and this value provides optimal performance for most applications. However, there can be additional performance improvements by empirically determining the appropriate bleed current value from the actual measurements for the intended application. The applicable range is 0 µA to 956.25 µA with 3.75 µA steps. IBLEED = CP_BLEED × 3.75 µA where CP_BLEED is an integer value (0 to 255). Figure 94 shows an example of 100 kHz offset phase noise vs. CP_BLEED. –102 –100 –98 –96 –94 –92 –90 –88 –86 –84 10 0 20 30 40 50 60 70 80 90 100 110 120 CP_BLEED TA = +85°C TA = +25°C TA = –40°C Figure 94. 100 kHz Offset Phase Noise vs. CP_BLEED, LO Frequency = 29.995 GHz, CP_CURRENT = 4.2 mA Figure 95 is an example of 100 kHz offset phase noise vs. LO frequency with a CP_BLEED value of 115 (431.25 µA). The CP_CURRENT was 4.2 mA and the LO frequency step size was 10 MHz. At each integer boundary, the CP_BLEED was disabled, resulting in approximately −1 dBc/Hz improvement. –105 –104 –103 –102 –101 –100 –99 –98 –97 –96 –95 –94 –93 –92 –91 –90 28.0 28.5 29.0 29.5 30.0 LO FREQUENCY (GHz) Figure 95. 100 kHz Offset Phase Noise vs. LO Frequency, CP_BLEED = 115, CP_CURRENT = 4.2 mA |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |