| Electronic Components Datasheet Search |
|
6402 Datasheet(PDF) 79 Page - Intel Corporation |
|
|
|||||||||||||||||||||||||||||
6402 Datasheet(HTML) 79 Page - Intel Corporation |
|
79 / 250 page ![]() Intel® 6400/6402 Advanced Memory Buffer Datasheet 79 SMBus Interface 7.1.3.1 Configuration Register Read Protocol Configuration reads are accomplished through an SMBus write(s) and later followed by an SMBus read. The write sequence is used to initialize the Bus Number, Device, Function, and Register Number for the configuration access. The writing of this information can be accomplished through any combination of the supported SMBus write commands (Block, Word, or Byte). The Internal Command field for each write should specify Read DWord. After all the information is set up, the last write (End bit is set) initiates an internal configuration read. If an error occurs during the internal access, the last write command will receive a NACK. A status field indicates abnormal termination and contains status information such as target abort, master abort, and time-outs. The status field encoding is defined in the following table. Examples of configuration reads are illustrated below. All of these examples have PEC (Packet Error Code) enabled. If the master does not support PEC, then bit 4 of the command would be cleared and there would not be a PEC phase. For the definition of the diagram conventions below, refer to the SMBus Specification, Rev. 2.0. For SMBus read transactions, the last byte of data (or the PEC byte if enabled) is NACKed by the master to indicate the end of the transaction. For diagram compactness, “Register Number[]” is also sometimes referred to as “Reg Number” or “Reg Num”. The following example uses byte reads. Table 7-3. Status Field Encoding for SMBus Reads Bit Description 7 Reserved 6 Reserved 5 Reserved 4 Internal Target Abort 3:1 Reserved 0 Successful Figure 7-1. SMBus Configuration Read (Block Write / Block Read, PEC Enabled) S X011_XXX W A Cmd = 11010010 A Sr X011_XXX R A Byte Count = 5 A Status A Data[31:24] A Data[23:16] A Data[15:8] A Data[7:0] A S X011_XXX W A Cmd = 11010010 A Byte Count = 4 A Reserved A Device/Function A Reg Number[15:8] A Reg Number [7:0] A PEC A P PEC N P |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |