21 / 51 page ![]() AS1860 Akros Silicon, Inc. 6399 San Ignacio Avenue, Suite 250, San Jose, CA 95119 USA 408.746.9000 http://www.AkrosSilicon.com 21 As the supply voltage from the PSE increases from 0V, the AS1860 transitions through these operating states: These five operating states have specific transition criteria per the IEEE® PoE standard. PD Reset State When the voltage supplied to the AS1860 drops below VRESET_MIN, the device enters the reset state. In reset state, the AS1860 consumes very little power, the power supply to the PD is disconnected and state condition reverts to pre-classification. PD Signature Detection State During signature detection, the PSE applies a voltage to read the PD power signature and validates the PD as standards compliant. To ascertain the power signature the PSE applies two voltages in the signature voltage range and extracts a signature resistance value from the I-V slope. The AS1860 signature resistance is specified by an external resistor connected between the RSIG pin and the 48VIN pin. A 26.7kΩ external signature resistor is recommended. Upon successful detection of the PD by a PSE the AS1860 disconnects the external signature resistor at the RSIG pin to conserve power. PD Classification State Each class represents a power allocation level for the PD and allows the PSE to manage power requirements between multiple PDs. The AS1860 supports both IEEE® Std. 802.3af, and two event classification per IEEE® Std. 802.3at (PoE+), see Figure 29. The AS1860 allows the user to set required classification current via an external resistor connected between the RCLASS pin and 48RTN (Paddle #1). See Table 14 for recommended RCLASS resistor values. During the classification state the PSE presents a voltage between 14.5V and 20.5V which the AS1860 terminates in the RCLASS resistor resulting in a PSE measurable current, Iclass. Table 14 - Classification Map Class Power (Watts) Iclass Rclass 0 0.44-12.95 0 - 4 mA 2.05MΩ, 1% 1 0.44-3.84 9 - 12 mA 221kΩ, 1% 2 3.84-6.49 17 - 20 mA 115kΩ, 1% 3 6.49-12.95 26 - 30 mA 75kΩ, 1% 4 12.96-25.5 36 - 44 mA 49.9kΩ, 1% Upon successful classification of the PD by a PSE the AS1860 disconnects the external classification resistor at the RCLASS pin. PD Idle State In the Idle state (between Classification and the ON state) the AS1860 current is limited to monitoring circuitry needed for detection of the ON state threshold. PD ON State At a voltage of 42V or higher the AS1860 enters the ON state and full power is available via the DC-DC Controller. In IEEE® PoE compliant systems the PSE remotely detects either a DC or AC Maintain Power Signature (MPS) state in the PD platform. If either the PD PoE DC current is less than 10mA or the PD input AC impedance is above 26.25KΩ the PSE may disconnect power. To guarantee such a power disconnect the PD PoE DC current must be <5mA, and, the AC impedance must be >2MΩ. AT Detection Operation The AS1860 has both software (I2C register bit) and hardware (AT_DET pin) capabilities to indicate a PoE Plus platform operating mode. The AT_DET detect feature (either pin or software) provides an indication when a PoE+ Power Source is available to the system, from either an Ethernet cable to a Type 2 PSE or via use of Local Power Supply using the LDET input pin. In the case of hardware mode the AT_DET pin can be used to directly drive an LED indicator. Since this pin is on the secondary side of the AS1860 the user can interface it directly to the PD system controller without additional interfacing isolation circuitry. A typical platform usage of AT_DET is to self-configure the PD platform based on available power. If not operating on Local Power, the AT_DET indicator stays low during the PD Reset, Detection and Classification phases. This indicator will be set high once the PD recognizes completion of the 2-event Physical Layer Classification as initiated by a Type 2 PSE. The pin will remain high and be reset to zero after the occurrence of a PD Reset State (48VIN < 2.7V) or a power-down event. AT_DET remains low if the PSE partner is identified to be Type 1 during the classification phase. Local Power Source As mentioned above the AS1860 may also be powered from a DC source other than the Ethernet line. This local source is detected when the voltage at the LDET pin is 2 volts (typ) below the voltage at pin 48VIN. When such a local power is present the AS1860 will disable the power FET and thereby disconnect from the PoE power source. When operating in Local Power mode the AT_DET pin does not indicate the far end PSE, and is always HIGH (see Table 15). |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |