| Electronic Components Datasheet Search |
|
WM0011 Datasheet(PDF) 142 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
WM0011 Datasheet(HTML) 142 Page - Cirrus Logic |
|
142 / 233 page ![]() WM0011 Production Data w PD, Rev 4.1, August 2013 142 TRAX_CONFIG – TRAX TRACE BUFFER CONFIGURATION REGISTER The TRAX Trace Buffer can be accessed via the JTAG interface, or via the internal APB interface. Only one of these can be supported at any time - the selected method is determined by the TRAX_MODE bit. When APB mode is selected, the APB_RST bit can be used to reset the TRAX module. When JTAG mode is selected, the TRAX module can be reset using the TRST ¯¯¯¯¯ pin. Note that the TRAX clock enable bit (TRAX_CLK_ENA) is on the CCM_CLK_ENA register. TRAX_CONFIG TRAX TRACE BUFFER CONFIGURATION REGISTER Address = 0xF0006_0000 Default value = 0x0000_0000 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 BITS FIELD NAME S/W ACCESS RESET VALUE FIELD DESCRIPTION 31:2 Reserved 1 TRAX_MODE RW 0x0 TRAX Access mode select 0 = JTAG control 1 = APB control 0 APB_RST RW 0x0 TRAX Module Reset 0 = Not reset 1 = Reset Only valid if APB mode is selected (TRAX_MODE=1) Table 96 TRAX_CONFIG Register TRAX_CTRL – TRAX CONTROL REGISTER The Trace function is enabled when the TR_ENA bit transitions from 0 to 1. The Trace function can stopped using the configurable ‘stop’ trigger derived from the PC Match function (see below). If a ‘stop’ trigger is enabled and asserted, then the Trace function will either stop immediately, or will continue for a ‘post-stop-trigger’ period, configured via the CNTU control bit and the TRAX_DLY_CNT register (see Table 103). Writing ‘0’ to the TR_ENA bit before a ‘stop’ trigger has been asserted will disable the Trace function immediately. If a ‘stop’ trigger has been asserted, and the TR_ENA bit is set to ‘0’ during the ‘post- stop-trigger’ period, then the Trace will continue until completion. Note that the TR_ENA bit is not automatically reset when the Trace function stops. This bit must be set to 0 prior to initiating a new Trace. The TRAX Control register allows configuration of the PC Match function. The contents of the TRAX Control register can be read at any time. When the Trace function is active (indicated via the TRACT bit in the TRAX_STS register), then only the TR_ENA bit can be written to. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |