Back Button WM0011 Datasheet HTML 143Page - Cirrus Logic WM0011 Datasheet HTML 144Page - Cirrus Logic WM0011 Datasheet HTML 145Page - Cirrus Logic WM0011 Datasheet HTML 146Page - Cirrus Logic WM0011 Datasheet HTML 147Page - Cirrus Logic WM0011 Datasheet HTML 148Page - Cirrus Logic WM0011 Datasheet HTML 149Page - Cirrus Logic WM0011 Datasheet HTML 150Page - Cirrus Logic WM0011 Datasheet HTML 151Page - Cirrus Logic Next Button
Zoom Inzoom in Zoom Outzoom out
 147 / 233 page
background image
WM0011
Production Data
w
PD, Rev 4.1, August 2013
147
TRAX_PC_MATCH – TRAX PC MATCH CONTROL REGISTER
When the PC Match function is enabled as a Trace Stop Event trigger (PCM_ENA=1), the processor
PC value is compared against the address held in the STOP_PC register, and is used to generate a
Stop condition for the Trace function.
Under default conditions, the PC Match stop condition is asserted when the PC value (corresponding
to the instruction about to be executed) is equal to the STOP_PC register value.
The PCML field selects how many of the least significant bits of the PC value and STOP_PC value
are ignored when identifying a PC Match condition.
The PCMS bit allows the matching logic to be inverted; it selects whether a Stop condition is
generated when the PC value and STOP_PC values are the same, or when they are not the same.
(Note that, in both cases, the match condition is also governed by the LSB mask function controlled
by PCML.)
TRAX_PC_MATCH
TRAX PC MATCH CONTROL REGISTER
Address = 0xF006_0018
Default value = 0x0000_0000
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
BITS
FIELD
NAME
S/W
ACCESS
RESET
VALUE
FIELD
DESCRIPTION
31
PCMS
RW
0x0
Trace Program Count Match inversion
Selects whether a PC Match Stop condition is triggered when the PC
value and STOP_PC value are the same, or when they are not the
same. (In both cases, the match condition is also subject to the mask
length, PCML.)
0 = PC Match when PC value and STOP_PC are equal
1 = PC Match when PC value and STOP_PC are not equal
30:5
Reserved
0x000_
0000
4:0
PCML
RW
0x00
Trace Program Count Match mask length
Selects how many least significant bits of the PC value and STOP_PC
value are ignored when identifying a PC Match condition.
Table 102 TRAX_PC_MATCH Register



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com