Back Button WM0011 Datasheet HTML 173Page - Cirrus Logic WM0011 Datasheet HTML 174Page - Cirrus Logic WM0011 Datasheet HTML 175Page - Cirrus Logic WM0011 Datasheet HTML 176Page - Cirrus Logic WM0011 Datasheet HTML 177Page - Cirrus Logic WM0011 Datasheet HTML 178Page - Cirrus Logic WM0011 Datasheet HTML 179Page - Cirrus Logic WM0011 Datasheet HTML 180Page - Cirrus Logic WM0011 Datasheet HTML 181Page - Cirrus Logic Next Button
Zoom Inzoom in Zoom Outzoom out
 177 / 233 page
background image
WM0011
Production Data
w
PD, Rev 4.1, August 2013
177
SPI_SS_CFG– SPI SLAVE SELECT CONFIGURATION REGISTER
SPI_SS_CFG
SPI SLAVE SELECT CONFIGURATION REGISTER
Address = 0xF030_0030
Default value = 0x0000_0000
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
BITS
FIELD
NAME
S/W
ACCESS
RESET
VALUE
FIELD
DESCRIPTION
31:21
Reserved
0
23:20
SCLK_WAIT
RW
0x0
SPI Clock Wait (Valid in SPI Master Mode only): determines the wait
time between successive data transfers in multiple-transfer mode
(SPI_MT_ENA=1). The register value sets the minimum number of
SPISCLK clock cycles between back-to-back transfers. Note that,
during this wait time, SPISS
¯¯¯¯¯ remains active, but SPISCLK does not
toggle.
19:16
SS_WAIT
RW
0x0
Slave Select Wait (Valid in SPI Master Mode only): determines the wait
time between successive data transfers in single-transfer mode
(SPI_MT_ENA=0). The register value sets the minimum number of
SPISCLK clock cycles between the de-assertion of SPISS
¯¯¯¯¯ and the re-
assertion of SPISS
¯¯¯¯¯.
15:12
SS_HOLD
RW
0x0
Slave Select Hold (Valid in SPI Master Mode only):
The register value sets the minimum number of SPISCLK clock cycles
to wait from the last SPISCLK transition to de-assertion of SPISS
¯¯¯¯¯.
11:8
SS_SETUP
RW
0x0
Slave Select Setup (Valid in SPI Master Mode only):
The register value sets the minimum number of SPISCLK clock cycles
to wait from the assertion of SPISS
¯¯¯¯¯to the first SPISCLK transition.
7:3
Reserved
0x00
2
SS_POL
RW
0x0
Slave Select active level select (Master or Slave modes):
0 = Active low
1 = Active high
1:0
Reserved
0x0
Table 125 SPI_SS_CFG Register
Note that setting (or resetting) the SS_POL bit may cause SS_TE, SS_LE and CYC_DONE to be set
in the status register; these may need to be cleared out before operations begin. It is recommended to
set SPI_ENA=0 whilst configuring the SPI module. SPI_ENA should be set to 1 after the
SPI_SS_CFG register (and other registers) have been set to the desired values.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com