| Electronic Components Datasheet Search |
|
MAX8772 Datasheet(PDF) 34 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX8772 Datasheet(HTML) 34 Page - Maxim Integrated Products |
|
34 / 47 page ![]() MAX8770/MAX8771/MAX8772 Dual-Phase, Quick- PWM Controller for IMVP-6+ CPU Core Power Supplies 34 ______________________________________________________________________________________ CONFIDENTIAL INFORMATION – RESTRICTED TO INTEL® IMVP-6 LICENSEES Forced-PWM Operation (Normal Mode) During soft-start, soft-shutdown, and normal opera- tion—when the CPU is actively running (DPRSLPVR = low, Table 5)—the MAX8770/MAX8771/MAX8772 oper- ate with the low-noise, forced-PWM control scheme. Forced-PWM operation disables the zero-crossing comparators of all active phases, forcing the low-side gate-drive waveforms to be constantly the complement of the high-side gate-drive waveforms. This keeps the switching frequency constant and allows the inductor current to reverse under light loads, providing fast, accurate negative-output-voltage transitions by quickly discharging the output capacitors. Forced-PWM operation comes at a cost; the no-load +5V bias supply current remains between 10mA to 50mA per phase, depending on the external MOSFETs and switching frequency. To maintain high efficiency under light-load conditions, the processor may switch the controller to a low-power, pulse-skipping control scheme after entering suspend mode. PSI determines how many phases are active when operating in forced-PWM mode (DPRSLPVR = low). When PSI is pulled low, the main phase remains active but the secondary phase is disabled (DH2 and DL2 forced low). Light-Load Pulse-Skipping Operation (Deeper Sleep) When DPRSLPVR is pulled high, the MAX8770/ MAX8771/MAX8772 operate with a single-phase, pulse-skipping mode. The pulse-skipping mode enables the driver’s zero-crossing comparator, so the controller pulls DL1 low when its current-sense inputs detect “zero” inductor current. This keeps the inductor from discharging the output capacitors and forces the controller to skip pulses under light-load conditions to avoid overcharging the output. When pulse skipping, the controller blanks the upper PWRGD and CLKEN thresholds, and also blanks PHASEGD high impedance for the MAX8771. Upon entering pulse-skipping operation, the controller tem- porarily sets the OVP threshold to 1.80V, preventing false OVP faults when the transition to pulse-skipping operation coincides with a downward VID code change. Once the error amplifier detects that the output voltage is in regulation, the OVP threshold tracks the selected VID DAC code. The MAX8770/MAX8771/ MAX8772 automatically use forced-PWM operation dur- ing soft-start and soft-shutdown, regardless of the DPRSLPVR and PSI configuration. Automatic Pulse-Skipping Switchover In skip mode (DPRSLPVR = high), an inherent automat- ic switchover to PFM takes place at light loads (Figure 8). This switchover is affected by a comparator that truncates the low-side switch on-time at the inductor current’s zero crossing. The zero-crossing comparator senses the inductor current across the low-side MOSFETs. Once VLX drops below the zero crossing comparator threshold (see the Electrical Characteristics table), the comparator forces DL low (Figure 2). This mechanism causes the threshold between pulse-skip- ping PFM and nonskipping PWM operation to coincide with the boundary between continuous and discontinu- ous inductor-current operation. The PFM/PWM crossover occurs when the load current of each phase is equal to 1/2 the peak-to-peak ripple current, which is a function of the inductor value (Figure 8). For a bat- tery-input 7V to 20V range, this threshold is relatively constant, with only a minor dependence on the input voltage due to the typically low duty cycles. The total load current at the PFM/PWM crossover threshold (ILOAD(SKIP)) is approximately: where ηTOTAL is the number of active phases. The switching waveforms may appear noisy and asyn- chronous when light loading activates pulse-skipping operation, but this is a normal operating condition that results in high light-load efficiency. Trade-offs between PFM noise and light-load efficiency are made by vary- I TV L VV V LOAD SKIP TOTAL SW OUT IN OUT IN () = ⎛ ⎝⎜ ⎞ ⎠⎟ − ⎛ ⎝⎜ ⎞ ⎠⎟ η Figure 8. Pulse-Skipping/Discontinuous Crossover Point IPEAK ILOAD = IPEAK/2 TIME 0 L V BATT – VOUT ∆t ∆i ON-TIME |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |