Back Button AL103 Datasheet HTML 36Page - List of Unclassifed Manufacturers AL103 Datasheet HTML 37Page - List of Unclassifed Manufacturers AL103 Datasheet HTML 38Page - List of Unclassifed Manufacturers AL103 Datasheet HTML 39Page - List of Unclassifed Manufacturers AL103 Datasheet HTML 40Page - List of Unclassifed Manufacturers AL103 Datasheet HTML 41Page - List of Unclassifed Manufacturers AL103 Datasheet HTML 42Page - List of Unclassifed Manufacturers AL103 Datasheet HTML 43Page - List of Unclassifed Manufacturers AL103 Datasheet HTML 44Page - List of Unclassifed Manufacturers Next Button
Zoom Inzoom in Zoom Outzoom out
 40 / 66 page
background image
AL103 Revision 1.0
9/00
Reference Only / Allayer Communications
40
3
L2Trunk
Layer 2 Trunk Loading Method.
0: Port based loading. Trunking decisions will be based on Trunk Port
Assignment Registers.
1: MAC address based loading. Trunking decisions will be based on
source port MAC addresses.
2
TimeoutEN
Frame Time Out Enable.
0: Device will not timeout frames based on MaxDelay.
1: Device will timeout frames.
1~0
Reserved
Reserved (Must set to 00).
Table 21: System Configuration Register II (Register 01)
BIT
NAME
DESCRIPTION
15~8
MaxAge
Maximum Age For Dynamically Learned MAC Entries.
0000 0000: 1 sec. to 1111 1111: 256 sec.
7~6
MaxDelay
Maximum Frame Transition Delay Through The Switch.
00: 1 second.
01: 2 seconds.
10: 3 seconds.
11: 4 seconds.
5~4
MaxStorm
Maximum Number of Broadcast Frames That Can Be Accumulated In
Each Input Frame Buffer.
00: 16 frames.
01: 32 frames.
10: 48 frames.
11: 64 frames.
3
SuperMAC
0: Disable. Device will perform the IEEE standard exponential back-off
algorithm when a collision occurs.
1: Enable. When collisions occur, the AL103 will back off up to 3 slots.
2
REC
Retry on Excessive Collision.
0: Normal collision handling.
1: Retry transmission after 16 consecutive collisions.
1~0
L2TbitSel
Select the Bits Position for MAC Address To Trunk Assignment.
00: Source MAC address [1:0].
01: Source MAC address [3:2].
10: Source MAC address [5:4].
11: Source MAC address [7:6].
Table 20: System Configuration Register I (Register 00) (Continued)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com