62 / 70 page ![]() 62 FIFO Interrupt Interface Transmit Transmitting messages with Programmed I/O using FIFO Interrupt requires writing a fixed number of data bytes, usually related to the threshold, whenever the FIFO Interrupt becomes active. An appropriate FIFO Threshold value allows the host to efficiently satsify the FIFO service requests until the message transmission is complete. For slow systems, the FIFO can be manually filled with transmit data before the transmitter is enabled. NOTE: The FIFO will automatically request service before the transmitter is activated if the FIFO Threshold is greater than zero. DMA Enable IOR String Move FIFO Data READ Status READ FIFO NOT EMPTY FIGURE 29 - PROGRAMMED I/O READ TIMING DMA Enable IOW String Move FIFO Data WRITE Status READ FIFO FULL FIGURE 30 - PROGRAMMED I/O WRITE TIMING |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|