Back Button HCPL316J Datasheet HTML 3Page - Agilent(Hewlett-Packard) HCPL316J Datasheet HTML 4Page - Agilent(Hewlett-Packard) HCPL316J Datasheet HTML 5Page - Agilent(Hewlett-Packard) HCPL316J Datasheet HTML 6Page - Agilent(Hewlett-Packard) HCPL316J Datasheet HTML 7Page - Agilent(Hewlett-Packard) HCPL316J Datasheet HTML 8Page - Agilent(Hewlett-Packard) HCPL316J Datasheet HTML 9Page - Agilent(Hewlett-Packard) HCPL316J Datasheet HTML 10Page - Agilent(Hewlett-Packard) HCPL316J Datasheet HTML 11Page - Agilent(Hewlett-Packard) Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 33 page
background image
7
Regulatory Information
The HCPL-316J has been approved by the following
organizations:
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01.
IEC/EN/DIN EN 60747-5-2
Insulation Characteristics*
Description
Symbol
Characteristic
Unit
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage
≤ 150 Vrms
I - IV
for rated mains voltage
≤ 300 Vrms
I - III
for rated mains voltage
≤ 600 Vrms
I - II
Climatic Classification
55/100/21
Pollution Degree (DIN VDE 0110/1.89)
2
Maximum Working Insulation Voltage
VIORM
891
VPEAK
Input to Output Test Voltage, Method b**
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
VPR
1670
VPEAK
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a**
VIORM x 1.5 = VPR, Type and Sample Test, tm = 60 sec,
VPR
1336
VPEAK
Partial Discharge < 5 pC
Highest Allowable Overvoltage**
(Transient Overvoltage tini = 10 sec)
VIOTM
6000
VPEAK
Safety-limiting values - maximum values allowed in the event of
a failure, also see Figure 2.
Case Temperature
TS
175
°C
Input Power
PS, INPUT
400
mW
Output Power
PS, OUTPUT
1200
mW
Insulation Resistance at TS, VIO = 500 V
RS
>109
Ω
Figure 2. Dependence of Safety Limiting Values on Temperature.
* Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in
application. Surface mount classification is class A in accordance with CECCOO802.
** Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations
section IEC/EN/DIN EN 60747-5-2, for a detailed description of Method a and Method b partial discharge test profiles.
0
0
TS – CASE TEMPERATURE – °C
200
1200
800
25
1400
50
75 100
400
150 175
PS, OUTPUT
PS, INPUT
125
200
600
1000
UL
Recognized under UL 1577, component recognition
program, File E55361.
CSA
Approved under CSA Component Acceptance Notice #5,
File CA 88324.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com