| Electronic Components Datasheet Search |
|
AM29BDD160G Datasheet(PDF) 42 Page - Advanced Micro Devices |
|
|
|||||||||||||||||||||||||||||
AM29BDD160G Datasheet(HTML) 42 Page - Advanced Micro Devices |
|
42 / 80 page ![]() 40 Am29BDD160G SecSi Sector Entry Command The SecSi Sector Entry command enables the SecSi (OTP) sector to overlay the 8 KB outermost sector in the small (25%) bank. The SecSi sector overlays 00000h–0003Fh for the top boot block configuration and 7FFC0h–7FFFFh for the bottom boot block confi- uration. Address range 00040h–007FFh for the top boot block and 7F800h–7FFBFh return invalid data when addressed with the SecSi sector enabled. The following commands are permitted after issuing the SecSi Sector Entry command: 1. Autoselect 2. Password Program (x16 and x32) 3. Password Verify 4. Password Unlock (x16 and x32) 5. Read/Reset 6. Program 7. Chip and Sector Erase 8. SecSi Sector Protection Bit Program 9. PPB Program 10.All PPB Erase 11. PPB Lock Bit Set 12.DYB Write 13.DYB/PPB/PPB Lock Bit Verify 14.Security Reset 15.Configuration Register Write 16.Configuration Register Read The following commands are unavailable when the SecSi sector is enabled. Issuing the following com- mands while the SecSi sector is enabled results in the command being ignored. 1. Unlock Bypass 2. CFI 3. Accelerated Program 4. Program and Sector Erase Suspend 5. Program and Sector Erase Resume The SecSi Sector Entry command is allowed when the device is in either program or erase suspend modes. If the SecSi sector is enabled, the program or erase suspend command is ignored. This prevents resuming either programming or erasure on the SecSi sector if the overlaid sector was undergoing programming or erasure. The host system must ensure that the device resume any suspended program or erase operation after exiting the SecSi sector. Executing any of the PPB program/erase commands, or Password Unlock command results in the small bank (25% bank) returning the status of these oper- ations while they are in progress, thus making the SecSi sector unavailable for reading. If the SecSi sector is enabled while the DYB command is issued, the DYB for the overlaid sector is NOT updated. Reading the DYB status using the PPB Lock Bit/DYB- DYB verify command when the SecSi sector is enabled returns invalid data. Password Program Command The Password Program Command permits program- ming the password that is used as part of the hardware protection scheme. The actual password is 64-bits long. Depending upon the state of the WORD# pin, multiple Password Program Commands are required. For a x16 bit data bus, 4 Password Pro- gram commands are required to program the password. For a x32 bit data bus, 2 Password Pro- gram commands are required. The user must enter the unlock cycle, password program command (38h) and the program address/data for each portion of the password when programming. There are no pro- visions for entering the 2-cycle unlock cycle, the password program command, and all the password data. There is no special addressing order required for programming the password. Also, when the pass- word is undergoing programming, Simultaneous Operation is disabled. Read operations to any mem- ory location will return the programming status. Once programming is complete, the user must issue a Read/Reset command to return the device to nor- mal operation. Once the Password is written and verified, the Password Mode Locking Bit must be set in order to prevent verification. The Password Pro- gram Command is only capable of programming “0”s. Programming a “1” after cell is programmed as a “0” results in a time-out by the Embedded Program Algorithm™ with the cell remaining as a “0”. The password is all F’s when shipped from the factory. All 64-bit password combinations are valid as a pass- word. Password Programming is permitted if the SecSi sec- tor is enabled. Password Verify Command The Password Verify Command is used to verify the Password. The Password is verifiable only when the Password Mode Locking Bit is not programmed. If the Password Mode Locking Bit is programmed and the user attempts to verify the Password, the device will always drive all F’s onto the DQ data bus. The Password Verify command is permitted if the SecSi sector is enabled. Also, the device will not op- erate in Simultaneous Operation when the Password Verify command is executed. Only the password is returned regardless of the bank address. The lower two address bits (A0:A-1) are valid during the Pass- word Password Protection Mode Locking Bit Program Command The Password Protection Mode Locking Bit Program Command programs the Password Protection Mode Locking Bit, which prevents further verifies or up- dates to the Password. Once programmed, the Password Protection Mode Locking Bit cannot be |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |