Back Button LTC7151S Datasheet HTML 13Page - Analog Devices LTC7151S Datasheet HTML 14Page - Analog Devices LTC7151S Datasheet HTML 15Page - Analog Devices LTC7151S Datasheet HTML 16Page - Analog Devices LTC7151S Datasheet HTML 17Page - Analog Devices LTC7151S Datasheet HTML 18Page - Analog Devices LTC7151S Datasheet HTML 19Page - Analog Devices LTC7151S Datasheet HTML 20Page - Analog Devices LTC7151S Datasheet HTML 21Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 17 / 38 page
background image
LT7182S
17
Rev. 0
For more information www.analog.com
OPERATION
LT7182S initialization typically requires 13ms. If CFG pins
are disabled (MFR_CONFIG_ALL_LT7182S bit 6 set to 1
in EEPROM), the initialization time is reduced to 10ms
(typical).
After initialization is complete, comparators monitor PVIN0
and PVIN1. The PVIN voltage must exceed the channel’s
programmable VIN_ON threshold for the channel to oper-
ate. By default, SHARE_CLK will be held low until PVIN0
exceeds VIN_ON for PAGE 0, or if PVIN0 falls below VIN_OFF.
By default, PVIN1 does not affect SHARE_CLK. The default
behavior for both channels is to turn off and remain off
if SHARE_CLK is low. See the MFR_CHAN_CONFIG_
LT7182S command in the LT7182S PMBus/I2C Reference
Manual for information on how to configure this behavior.
The RUN pin pull-down current (1.5mA typical) is released
by the LT7182S after the device completes POR initializa-
tion and the first time the channel’s PVIN potential exceeds
the VIN_ON threshold.
SOFT-START
When all conditions required for startup have been met,
and a channel is enabled, the LT7182S waits for the com-
manded turn-on delay and ramps the target output voltage
up to the commanded voltage set-point. The soft-start rise
time is set by the TON_RISE command, default 1ms. The
turn-on delay is set by TON_DELAY, which is 0ms by fac-
tory default. The LT7182S PWM always uses pulse-skip
mode during soft-start, which allows the regulator to start
up into a pre-biased load. If forced continuous conduc-
tion mode is selected (MFR_PWM_MODE_LT7182S bit
0 cleared to 0), the channel will transition to continuous
conduction mode after the commanded voltage set-point
is reached.
SHUTDOWN
The LT7182S can be programmed to turn off immediately
or to sequence off.
When sequencing off, the LT7182S waits for the turn-off
delay then performs a soft-stop ramp in which the regu-
lation target voltage is ramped down to zero. The turn-off
delay is set by the TOFF_DELAY command, default zero.
The target voltage ramp-down time is set by TOFF_FALL,
default 2ms. By default, the channel will ramp down in
forced continuous conduction mode. The ramp-off behav-
ior can be configured using MFR_PWM_MODE_LT7182S.
Sequencing off occurs if OPERATION is set to 0x40, or if
the RUN pin is de-asserted and ON_OFF_CONFIG bit 0 is
set to 0 and bit 2 is set to 1.
When immediate turn-off occurs, the regulator ramps
the inductor current to zero as quickly as possible and
then stops switching. In this case, the output voltage will
decay based only on the load current and the optional
internal 250Ω pull-down. The internal 250Ω pull-down
can be disabled by clearing bit 6 of MFR_CHAN_CONFIG_
LT7182S. Immediate shutdown occurs in any the follow-
ing situations:
• PVIN falls below the VIN_OFF threshold
• If the OPERATION command is cleared to 0x00, if
ON_OFF_CONFIG bit 3 is set to 1
• A fault condition occurs which causes the output to
turn off
• The RUN pin is de-asserted and ON_OFF_CONFIG
has been configured such that RUN pin de-assertion
causes immediate shutdown (ON_OFF_CONFIG bits 0
and 2 both set to 1)
• The FAULT pin for the channel is pulled low externally,
unless MFR_FAULT_RESPONSE has been cleared to
0x00.
• Loss of SHARE_CLK, unless bit 2 of MFR_CHAN_
CONFIG_LT7182S has been cleared
WARNING AND FAULT HANDLING
The LT7182S continuously monitors the system for fault
and warning conditions.
Fault responses are configurable using the correspond-
ing FAULT_RESPONSE commands, such as VOUT_UV_
FAULT_RESPONSE, VOUT_OV_FAULT_RESPONSE, etc.
Possible fault responses are as follows:
• Continue Operation (Ignore)
• Shut down immediately and retry if fault condition is
no longer present



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com