| Electronic Components Datasheet Search |
|
LTC4261 Datasheet(PDF) 32 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LTC4261 Datasheet(HTML) 32 Page - Analog Devices |
|
32 / 82 page ![]() LTC4284 32 Rev. B For more information www.analog.com APPLICATIONS INFORMATION the RC network should represent the thermal behavior of a single MOSFET, since the TMR pull-up current is only related to power dissipation in the channel 1 MOSFET. When TMR reaches 2.048V (representing the maximum allowable temperature rise in the MOSFET), both GATE1 and GATE2 are turned off and an overcurrent fault is logged in FAULT register 0x04. If the dV/dt inrush control is enabled by setting the DVDT bit in CONTROL_1 register 0x0A, the inrush current dur- ing startup may not be evenly distributed between the two channels due to MOSFET threshold mismatch. Therefore, a proper RAMP capacitor must be selected so that the inrush current is lower than the startup current limit of each channel, not the sum of the two channels. High Stress Staged Start Mode (Mode 3) The two GATE drivers of the LTC4284 can also be con- figured to operate in high stress staged start mode by connecting MODE to VIN. In this mode GATE1 drives a high SOA MOSFET (M1) for startup and to withstand overstresses and GATE2 drives less expensive bypass MOSFETs (M2A and M2B) with low RDS(ON) (their SOAs are usually low, too) to carry the load, as shown in Figure 10. Similar to the parallel mode, the high stress staged start mode also works well for systems where large input steps or supply surges are inevitable. M1 must be selected with large enough SOA to withstand these conditions, in which M1 not only carries the full load current, but also needs to deliver the capacitive current to charge up the load. See Input Step and Optimum Output Ramp for details. At power-up, GATE1 is turned on first to charge the load and GATE2 is held off. The startup inrush control can be configured into either current limit mode or dV/ dt mode using the DVDT bit in CONTROL_1 register 0x0A. If dV/dt mode is selected, the inrush current must be limited substantially lower than the startup current limit. As illustrated in Figure 11, when GATE1 is fully enhanced (VGATE1 > VGATE(TH)) and the load capacitor is fully charged (VDRAIN < 2.048), GATE2 is turned on. R3 487k 1% CVCC 1µF 0.25m RS1 8 × 2m M2A IPT020N10N3 RIN 4 × 1k IN SERIES 0.25W EACH CIN 0.1µF 4 4 4 M2B 4284 F10 IPT020N10N3 M1 IXTQ170N10P RG1A 10 RG1 2k RG2A 10 RG2B 10 RD 100k R2 14.3k 1% R1 10k 1% RRT 200k 1% RRB 5.11k 1% RDT 200k 1% CG1 100nF CG2 22nF CE2 15nF CE3 150nF RE2 30.1k 1% CL 2000µF RE3 1.13M 1% CUV 100nF CE1 3.3nF RE1 4.02k 1% CR 68nF RDB 5.11k 1% –48V RTN UVH UVL OV –48V INPUT ADIN1-4 TMR VEE MODE INTVCC SENSE1– SENSE1+ GATE1 SENSE2– GATE2 DRAIN VZ VIN RTNS SCL SDAI SDAO ALERT# ADIO1-4 PGIO1-4 LTC4284 –48V RTN (SHORT PIN) VEE ADC– DRNS SENSE2+ ADC+ DVDT = 1 THERM_TMR = 1 ILIM = 1010 FB = 11 FB_DIS = 1 LPFB = 1 EN# UV = 38.6V UV RELEASE AT 43.1V OV = 71.9V OV RELEASE AT 70.7V VEE VEE VEE VEE VEE VEE RAMP VEE BATTERY OPERATED (SUBJECT TO –36V INPUT STEPS) VOUT VLOAD + – Figure 10. –48V/1800W Hot Swap Controller with SOA Timer and dV/dt Inrush Control in High Stress Staged Start Mode: GATE1 Drives High SOA MOSFET and GATE2 Drives Low RDS(ON) MOSFETs |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |