Back Button LTC4261 Datasheet HTML 37Page - Analog Devices LTC4261 Datasheet HTML 38Page - Analog Devices LTC4261 Datasheet HTML 39Page - Analog Devices LTC4261 Datasheet HTML 40Page - Analog Devices LTC4261 Datasheet HTML 41Page - Analog Devices LTC4261 Datasheet HTML 42Page - Analog Devices LTC4261 Datasheet HTML 43Page - Analog Devices LTC4261 Datasheet HTML 44Page - Analog Devices LTC4261 Datasheet HTML 45Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 41 / 82 page
background image
LTC4284
41
Rev. B
For more information www.analog.com
APPLICATIONS INFORMATION
Configuring PGIO and ADIO Pins
The LTC4284 has four PGIO pins and four ADIO pins, all
of which can be configured as general purpose inputs/
outputs using PGIO_CONFIG_1 register 0x10 and ADIO_
CONFIG register 0x12. Additionally, PGIO1 and PGIO2 can
be configured as two sequential inverted or non-inverted
power good signals, PGIO3 can be configured as inverted
or non-inverted power good input signal (see Power Good
Monitors and PGI Fault), and PGIO4 can be configured as
inverted or non-inverted external fault (see External Fault
and Auto-Retry). When configured as general purpose
outputs, the output data for PGIO1–PGIO4 and ADIO1–
ADIO4 are stored in bits[7:4] in PGIO_CONFIG_2 register
0x11 and bits[3:0] in ADC_CONFIG register 0x12, respec-
tively. When selected, ADIO1–ADIO4 are also monitored
by the on-board ADC (see Data Converters).
If the PGIO2_ACLB bit in CONTROL_1 register 0x0A is
set, PGIO2 is configured as an inverted indicator of active
current limit after startup. During startup PGIO2 is held
low. After the internal power good signal is latched, if
the OC_STATUS bit in FAULT_STATUS register 0x03 is
0, PGIO2 goes high impedance. If the OC_STATUS bit is
set to indicate that active current limit is engaged, PGIO2
is pulled low.
Regardless of the configurations, PGIO1–PGIO4 and
ADIO1–ADIO4 all have comparators monitoring the volt-
age on these pins with a threshold of 1.28V. The results
are stored in INPUT_STATUS register 0x02.
Design Examples
The design flow starts with specifying the maximum load
power and the operating voltage limits (line or battery
operated). A line operated system usually has a tightly
regulated supply voltage. A battery operated system usu-
ally has wide supply range and can experience large input
steps when replacing a dropping-out battery with a newly
charged one. An operation mode is then selected based
on the following guideline.
Single Driver Mode (Mode 1): <800W, line or battery
operated.
Parallel Mode (Mode 2): up to 1500W, line or battery
operated.
High Stress Staged Start Mode (Mode 3): >1500W, bat-
tery operated.
Low Stress Staged Start Mode (Mode 4): >1500W, line
operated.
This is a rough guide and the boundaries between dif-
ferent modes may shift up or down depending upon the
allowed budget of the MOSFETs.
Example 1: Design Procedure of Parallel Mode with
SOA Timer and Current Limit Startup
Consider a battery operated system with maximum load
power of 1200W, a supply voltage range of –36V to –72V
(–36V to –72V input step is allowed), and a load capaci-
tance of CL = 1000µF as shown in Figure 2. The parallel
mode is chosen based on the above guideline. In the par-
allel mode, GATE1 and GATE2 drive two parallel channels
of MOSFETs to charge the load capacitor simultaneously
at startup, share the load current after startup, and turn
off simultaneously upon a fault condition such as output
overload or short-circuit.
The maximum load current is calculated as
IL(MAX) =
PL(MAX)
VS(MIN)
=
1200W
36V
= 33.3A
Step 1. Configure current limit and select current sense
resistors. Since a –36V to –72V input step is a valid oper-
ating condition, the current limit should be twice the maxi-
mum load current to minimize the temperature rise in the
MOSFETs following a large input step:
ILIM(OPT) = 2 ∙ IL(MAX) = 66.7A
With a constant power load, when the load voltage ramps
from 36V to 72V following the input step, the load cur-
rent is halved. The LPFB (load power foldback) bit in
CONFIG_1 register 0x0D is set to 1 so that the current
limit will be maintained at approximately twice the load
current during the output ramp.
In parallel mode, the two channels share the current
equally, so the maximum current each channel carries is
ICH(MAX) =
ILIM
2
= 33.3A



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com