Back Button LTC4261 Datasheet HTML 31Page - Analog Devices LTC4261 Datasheet HTML 32Page - Analog Devices LTC4261 Datasheet HTML 33Page - Analog Devices LTC4261 Datasheet HTML 34Page - Analog Devices LTC4261 Datasheet HTML 35Page - Analog Devices LTC4261 Datasheet HTML 36Page - Analog Devices LTC4261 Datasheet HTML 37Page - Analog Devices LTC4261 Datasheet HTML 38Page - Analog Devices LTC4261 Datasheet HTML 39Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 35 / 82 page
background image
LTC4284
35
Rev. B
For more information www.analog.com
APPLICATIONS INFORMATION
GATE2 turns off only if GATE1 turns off, which is differ-
ent from the high stress staged start mode where GATE2
turns off if GATE1 is in current limit. If an overcurrent
event occurs, both GATE1 and GATE2 stay in current
limit to share the stress (see Figure 14). Hence the cur-
rent sense pins for both current limit circuits on GATE1
and GATE2 must be connected to their corresponding
sense resistors.
In Figure 13 M1 is configured to deliver a very low inrush
current (0.34A) using a RAMP capacitor in the dV/dt
startup mode. The current limit is set to 0.72A by the
startup foldback ratio and a large sense resistor RS1. When
the load is fully charged (VDRAIN < 2.048) and the startup
MOSFET is fully enhanced (VGATE1 > VGATE(TH)), GATE2
is turned on. When M2A and M2B are fully enhanced
(VGATE2 > VGATE(TH)), the power good signals are asserted.
The condition to set the FET_BAD_STATUS bit in FAULT_
STATUS register 0x03 and starts the FET bad fault timer
in this mode is the same as in the parallel mode (see
Table 1). Since the FET bad fault timer is running during
the trickle startup while the load is slowly charged, the
timer duration must be programmed long enough using
the FTBD_DL bits in CONFIG_2 register 0x0E to avoid
turning off M1 too early.
During startup in dV/dt mode the TMR pull-up current
is disabled. It will not be enabled unless M1 goes into
current limit under a fault condition (e.g., start into short-
circuit). In normal operation after power good asserted,
the TMR pull-up current is enabled when both M1 and
M2A/M2B are in current limit. A single, small TMR capaci-
tor as shown in Figure 13 can be used to configure a brief
circuit breaker delay, which should be within the worst
SOA of M1 and M2A/M2B.
The startup inrush control can also be configured to cur-
rent limit by clearing the DVDT bit in CONTROL_1 register
0x0A. In this case the TMR pull-up current is enabled
during startup and is adjusted according to the foldback
ratio. An RC network that represents the electric model for
the thermal behavior of M1 should be connected to TMR.
Note that after startup when M2A and M2B are turned on,
the TMR pull-up current still relates to the power dissipa-
tion in M1. M1 should be selected so that its SOA is worse
than that of M2A or M2B. In this way M2A and M2B are
automatically protected when M1 turns off upon TMR
timeout in an overcurrent condition.
Single Driver Mode (Mode 1)
The LTC4284 can also be configured into the single driver
mode by floating the MODE pin. There are two possible
architectures in this mode. Figure  15 shows the first
architecture. GATE1 drives a single MOSFET or parallel
MOSFETS so that the LTC4284 behaves the same as a
single hot swap controller. GATE2 is left open and its cur-
rent limit circuit is disabled by shorting the SENSE2+/
SENSE2– pins to VEE.
Figure  16 shows the second architecture, in which
GATE1 and GATE2 are combined to drive a single chan-
nel of MOSFET(s). SENSE1+ and SENSE2+ are connected
together to the positive side of a single current sense resis-
tor and SENSE1− and SENSE2− are connected together to
the negative side of the resistor. In this way the current limit
circuits for both GATE1 and GATE2 are enabled so that the
GATE pull-up and pull-down currents are doubled, achiev-
ing a faster turn-off in response to fault conditions. The
single driver mode can be used in low to medium power
applications where a second gate driver is not needed.
Figure 14. Output-Short Protection in
Low Stress Staged Start Mode
TMR
GATE2
2.048V
VIN
MOSFET VTH
GATE1
VIN
MOSFET VTH
M1
CURRENT
ILIM1
ILIM2
LOAD
4284 F14
M2A/M2B
CURRENT



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com