Back Button LTC4261 Datasheet HTML 49Page - Analog Devices LTC4261 Datasheet HTML 50Page - Analog Devices LTC4261 Datasheet HTML 51Page - Analog Devices LTC4261 Datasheet HTML 52Page - Analog Devices LTC4261 Datasheet HTML 53Page - Analog Devices LTC4261 Datasheet HTML 54Page - Analog Devices LTC4261 Datasheet HTML 55Page - Analog Devices LTC4261 Datasheet HTML 56Page - Analog Devices LTC4261 Datasheet HTML 57Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 53 / 82 page
background image
LTC4284
53
Rev. B
For more information www.analog.com
APPLICATIONS INFORMATION
Figure 24. Individual Feed Current and Channel Current Monitoring
indicates fuse F2 is open. Additionally, chassis ground
is monitored with the ADIN1 pin as shown in Figure 23.
Figure 24 shows an example that monitors both individual
feed currents and individual channel currents using four
differential input pairs. Note that the ADIN2 – ADIN1 and
ADIN4 – ADIN3 inputs have a full scale of 33.301mV (pos-
itive terminals are at VEE), while the SENSE1+ − SENSE1−
and SENSE2+ − SENSE2− inputs have a normal full scale
of 32.768mV (negative terminals are at VEE).
The output voltage across the load may be calculated
from the measured RTNS and DRNS voltages. If a direct
measurement of the load voltage is desired, the circuit as
shown in Figure 25 may be used.
EEPROM
The LTC4284 has an onboard EEPROM to allow nonvola-
tile configuration and fault logging. The EEPROM registers
are denoted by EE_ in the first column of register Table 3.
The EEPROM registers may be read and written like any
other register except that the EEPROM takes about 2.2ms
to write data.
While the EEPROM is writing, the EEPROM_BUSY bit in
the SYSTEM_STATUS register is set. During this time,
the I2C interface will NACK attempted writes to EEPROM
registers. EEPROM registers will return 0xFF if read while
the EEPROM is busy. The FAULT_LOG_CONTROL register
is tied together with EEPROM and can’t be written while
EEPROM is busy. See the Fault Log section for more detail.
Other registers may be accessed while EEPROM write is
busy. When the EEPROM finishes writing, the EEPROM_
BUSY bit will be cleared and the EEPROM_WRITTEN bit
in the ADC_ALARM_LOG_1 register will be set.
If the corresponding EEPROM_WRITTEN_ALERT bit in
register ADC_ALERT_1 is set, a rising edge on EEPROM_
WRITTEN will set ALERT_GENERATED in the METER_
CONTROL register. As a result, the ALERT# pin is pulled
down. This will alert the host that the LTC4284 EEPROM
is ready for more accesses.
When the LTC4284 comes out of UVLO or receives a
REBOOT command, the contents of the EEPROM are cop-
ied to the corresponding operating registers. This process
takes about 1.3ms. During this time, the I2C bus is not
available. Any command code received will be NACKed.
Registers in the address range 0x0A through 0x40 corre-
spond to EEPROM locations 0xAA through 0xE0. Register
0x90 corresponds to EEPROM location 0xF0. The seven
EEPROM bytes in the EE_SCRATCH area are available
for any general purpose use. EEPROM is also used to
support the fault logging feature. See details in the Fault
Log section.
The WP pin prevents I2C writes to the EEPROM when
high. Attempts to write to the EEPROM while WP is high
will result in a NACK and no action. Fault log writes can
take place with WP high, except when the LTC4284 is in
single-wire broadcast mode. The EEPROM can be read
regardless of the WP pin setting. The current WP pin
status is available for reading at the WP_STATUS bit in
the REBOOT register.
Factory programmed parts may optionally have the
EEPROM locked. In this case the WP pin has no impact.
No EEPROM writes are possible. Fault logging is also
disabled when the EEPROM is locked. Bit EE_LOCK in
the METER_CONTROL register is a 1 when the EEPROM
is locked.
RS1
M2
M1
RS2
RF1
RF2
F1
F2
D1
D2
SENSE2–
GATE1 GATE2
LTC4284
4284 F24
SENSE2+
SENSE1– SENSE1+
ADIN3
ADIN4
ADIN1
ADIN2
INPUT2
INPUT1
VEE



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com