Back Button LTC4261 Datasheet HTML 21Page - Analog Devices LTC4261 Datasheet HTML 22Page - Analog Devices LTC4261 Datasheet HTML 23Page - Analog Devices LTC4261 Datasheet HTML 24Page - Analog Devices LTC4261 Datasheet HTML 25Page - Analog Devices LTC4261 Datasheet HTML 26Page - Analog Devices LTC4261 Datasheet HTML 27Page - Analog Devices LTC4261 Datasheet HTML 28Page - Analog Devices LTC4261 Datasheet HTML 29Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 25 / 82 page
background image
LTC4284
25
Rev. B
For more information www.analog.com
APPLICATIONS INFORMATION
is turned off to protect it from overheating. Traditional
circuit breakers often employ a fixed current charging an
external capacitor. The minimum timer timeout must be
set to allow the worst-case operating condition, such as
completely charging a large bypass capacitor at output
during startup or riding through a large input step. Then
upon fault conditions such as an output short-circuit at
full supply voltage, the MOSFET must withstand the large
power throughout the entire timer duration. Therefore,
the MOSFET must be selected to withstand the worst-
case SOA condition that occurs during any possible nor-
mal operating condition or fault condition. This not only
substantially increases the cost of the MOSFET, but also
complicates the design procedure and MOSFET selection.
The LTC4284 features a circuit breaker timer that better
fits the SOA of the MOSFET. When active current limit is
engaged, the OC_STATUS bit in FAULT_STATUS register
0x03 is set, and the TMR pin is activated and charged up
by a current proportional to the power dissipation in the
MOSFET that is driven by GATE1. The enabling condition of
the TMR charging current depends on the operation mode
(see OC_STATUS bit column in Table 1). A proper electric
model (RC network) is selected to represent the thermal
behavior of the MOSFET. When this RC network is con-
nected between TMR and VEE, the TMR voltage is propor-
tional to the rise in the MOSFET junction temperature. The
LTC4284 compares the TMR voltage to a fixed threshold
voltage of 2.048V, which represents the maximum allow-
able junction temperature rise in the MOSFET. When the
TMR voltage crosses this threshold, the LTC4284 turns off
the MOSFET. Therefore, to provide an appropriate protection
of a MOSFET, one simply selects the MOSFET that meets the
SOA requirement for allowable operating conditions such
as startup and input step. The MOSFET is automatically
turned off before it is subject to any condition that would
exceed its SOA rating.
Case 1. If active current limit is engaged in normal opera-
tion (power good signals are asserted), the TMR pull-up
current of the LTC4284 is proportional to the attenu-
ated drain voltage of the MOSFET at DRNS (top line in
Figure 7). This is proportional to the power dissipation
since the current through the MOSFET is fixed during
current limit (provided that foldback is disabled in normal
operation by setting the FB_DIS bit in CONFIG_1 register
0x0D). The TMR pull-up current in this condition is:
ITMR(UP)=111.1
µA
V
⎡
⎣⎢
⎤
⎦⎥
• VDRNS+2µA
where 111.1µA/V is the transconductance. The TMR pull-
up current reaches 202µA at VDRNS = 1.8V, which is tested
and specified. The offset of 2μA is introduced to guarantee
a minimum pull-up current that prevents TMR from hang-
ing in a resistive short-circuit condition.
The above equation also applies to startup in dV/dt mode
(DVDT bit in CONTROL_1 register 0x0A = 1), when the
current limit is triggered under a fault condition such as
a short-circuit. The accelerated timeout combined with
startup foldback (see Current Limit Foldback) protects
the startup MOSFET from overstress.
Case 2. During startup in dV/dt mode when current limit
is not engaged, TMR pull-up current is disabled:
ITMR(UP) = 0
In this case a 2μA pull down current holds TMR low if
the THERM_TMR bit in control register 0x0A is set. This
avoids undesired timeout before the load capacitor is fully
charged by the inrush current, which is set to such a low
level that the power dissipation in the startup MOSFET is
insignificant.
Figure 7. TMR Pull-Up Current vs ∆VSENSE1 and DRNS Voltage
∆VSENSE1 =
100% VILIM
96.7% VILIM
50% VILIM
20% VILIM
10% VILIM
DRNS VOLTAGE (V)
0
0.5
1
1.5
2
2.5
3
0
50
100
150
200
250
300
350
4284 F07



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com