55 / 82 page ![]() LTC4284 55 Rev. B For more information www.analog.com APPLICATIONS INFORMATION the first fault bit is set which leads to GATE1 and GATE2 low, the frozen copy of fault bits is closed and remains closed until after logging is complete. In the fault log, fault data comes from the frozen copy. During this time, fault information is still accumulated in the main fault registers. Servicing a Fault Log. After one fault log has been written, further fault log writes will be disabled until the first fault log has been serviced. The FAULT_LOG_START and FAULT_LOG_DONE bits can’t be set or cleared directly by I2C accesses. To prevent an accidental clearing of fault log information, a multi- byte sequence is required to fully service one fault log so another fault log can be written. The sequence is: 1. Write FAULT_LOG_CONTROL with FAULT_LOG_ UNLOCK set 2. Write a second time with FAULT_LOG_UNLOCK set and all other bits clear. This write will clear FAULT_ LOG_START and FAULT_LOG_DONE. 3. Write again with FAULT_LOG_UNLOCK, FAULT_LOG_ START and FAULT_LOG_DONE all clear. At this time, the FAULT_LOG_ENABLE and FAULT_LOG_ALERT bits may be set as desired. Additionally, to avoid inadvertently overwriting the logged data through I2C, bring WP high during servicing. Incomplete Fault Logs. A fault condition is a likely pre- cursor to an overall loss of power in the LTC4284. For accurate fault logging, the system design must provide sufficient external capacitance as described in Input Power Supply to hold INTVCC up during the time required to write 14 bytes to EEPROM. The fault log writing sequence described earlier provides a way to detect if the fault log doesn’t complete suc- cessfully. The first EEPROM write saves FAULT_LOG_ CONTROL with the FAULT_LOG_START bit set. Then the final EEPROM write saves FAULT_LOG_CONTROL with both FAULT_LOG_START and FAULT_LOG_DONE bits set. After a loss of power, the FAULT_LOG_CONTROL reg- ister is loaded back from the saved EEPROM copy. If power was lost before a fault log completed, the FAULT_LOG_CONTROL register will have FAULT_LOG_ START set, but not FAULT_LOG_END. Also after a loss of power, if the FAULT_LOG_ALERT bit is set and FAULT_ LOG_START, FAULT_LOG_DONE or FAULT_LOG_ UNLOCK are set, the ALERT# pin will be pulled down to alert the system that an unserviced fault log remains in the chip. Digital Interface The LTC4284 communicates with a bus master using a serial 2-wire interface, compatible with both I2C and SMBus. The 2-wire interface is supplemented by an SMBus-compatible ALERT# output. The LTC4284 is always a bus slave and doesn’t use clock stretching. Many LTC4284 applications require unidirectional isola- tors such as opto-couplers between the serial interface and the host system. For convenience of opto-coupling with the host, the SDA function is split into SDAI (input) and SDAO (output). For a conventional SDA line, tie SDAI and SDAO together. When using opto-couplers, connect the SDAI pin to the output of the incoming opto-coupler and connect the SDAO pin to the input of the outgoing opto-coupler (see Figure 2b). If the ALERT# line is used, connect it in the same way as the SDAO pin as shown in Figure 2b. Bus Compatibility The basic LTC4284 serial interface is compliant with I2C and SMBus AC and DC specifications. The timing is com- patible with 400Kbit operation for both. This includes the SMBus legacy tHD:DATO timing of 300ns minimum. In addition, the LTC4284 supports 1Mbit operation which is compatible with I2C FastMode+ and SMBus 3.0. To use this timing, the FAST_I2C_EN bit in the CONFIG_3 register must be set. This bit may be set to 1 as default by EEPROM, or it can be manually written to 1. If the bit is 0 before writing, the write must be done at 400Kbit or less. With FAST_I2C_EN set, tHD:DATO is reduced to allow higher speed transfers. The LTC4284 SDAO output is guaranteed to pull down 20mA. This allows the use of a lower value pull-up resistor to reduce the low-to-high delay time. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |