45 / 69 page ![]() RESET Time to enable I C 2 t r(run) t r(DMSTATE) t w(RESET) Internal Reset Initialization Complete TAS3202 www.ti.com SLES208B – JUNE 2009 – REVISED MARCH 2011 8.12 Reset Timing control signal parameters over recommended operating conditions (unless otherwise noted) PARAMETER MIN MAX UNIT tw(RESET) Pulse duration, RESET active 200 ns tr(DMSTATE) Time to outputs inactive 100 μs tr(run) Time to enable I2C 50 ms Figure 8-9. Reset Timing Copyright © 2009–2011, Texas Instruments Incorporated Electrical Specifications 45 Submit Documentation Feedback Product Folder Link(s): TAS3202 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|