21 / 54 page ![]() © 2011 Microchip Technology Inc. DS25048B-page 21 MCP3903 4.16 Crosstalk The crosstalk is defined as the perturbation caused by one ADC channel on the other ADC channel. It is a measurement of the isolation between the six ADCs present in the chip. This measurement is a two-step procedure: 1. Measure one ADC input with no perturbation on any other ADC (ADC inputs shorted). 2. Measure the same ADC input with a perturbation sine wave signal on the other ADC at a certain predefined frequency. The crosstalk is then the ratio between the output power of the ADC when the perturbation is present and when it is not divided by the power of the perturbation signal. A lower crosstalk value implies more independence and isolation between the six channels. The measurement of this signal is performed under the following conditions: •GAIN = 1, • PRESCALE = 1, • OSR = 256, • MCLK = 4 MHz Step 1 • CH0+=CH0-=AGND • CHn+=CHn-=AGND, n different than 0 Step 2 • CH0+=CH0-=AGND • CHn+ - CHn-=1VP-P @ 50/60 Hz (Full-scale sine wave) The crosstalk is then calculated with the following formula: EQUATION 4-10: 4.17 PSRR This is the ratio between a change in the power supply voltage and the ADC output codes. It measures the influence of the power supply voltage on the ADC outputs. The PSRR specification can be DC (the power supply is taking multiple DC values) or AC (the power supply is a sinewave at a certain frequency with a certain common mode). In AC, the amplitude of the sinewave is representing the change in the power supply. It is defined as: EQUATION 4-11: Where VOUT is the equivalent input voltage that the output code translates to with the ADC transfer function. In the MCP3903 specification, AVDD varies from 4.5V to 5.5V, and for AC PSRR a 50/60 Hz sinewave is chosen, centered around 5V with a maximum 500 mV amplitude. The PSRR specification is measured with DVDD = 3.3V. 4.18 CMRR This is the ratio between a change in the Common-Mode input voltage and the ADC output codes. It measures the influence of the Common-Mode input voltage on the ADC outputs. The CMRR specification can be DC (the common-mode input voltage is taking multiple DC values) or AC (the common-mode input voltage is a sinewave at a certain frequency with a certain common mode). In AC, the amplitude of the sinewave is representing the change in the power supply. It is defined as: EQUATION 4-12: Where VCM= (CHn+ + CHn-)/2 is the Common-Mode input voltage and VOUT is the equivalent input voltage that the output code translates to with the ADC transfer function. In the MCP3903 specification, VCM varies from -1V to +1V, and for AC specification a 50/60 Hz sinewave is chosen centered around 0V with a 500 mV amplitude. 4.19 ADC Reset Mode ADC Reset mode (called also soft reset mode) can only be entered through setting high the RESET<5:0> bits in the configuration register. This mode is defined as the condition where the converters are active but their output is forced to 0. The registers are not affected in this reset mode and retain their values. The ADCs can immediately output meaningful codes after leaving reset mode (and after the sinc filter settling time of 3/DRCLK). This mode is both entered and exited through setting of bits in the configuration register. Each converter can be placed in soft reset mode independently. The configuration registers are not modified by the soft reset mode. CTalk dB () 10 ΔCH0Power ΔCHnPower --------------------------------- ⎝⎠ ⎛⎞ log = PSRR dB () 20 ΔV OUT ΔAV DD ------------------- ⎝⎠ ⎛⎞ log = CMRR dB () 20 ΔV OUT ΔV CM ----------------- ⎝⎠ ⎛⎞ log = |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |