| Electronic Components Datasheet Search |
|
ADMC401 Datasheet(PDF) 30 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADMC401 Datasheet(HTML) 30 Page - Analog Devices |
|
30 / 60 page ![]() REV. B ADMC401 –30– cycle of the signals on CH and CL. The duty cycle registers are programmed in integer counts of the fundamental time unit, tCK, and define the desired on-time of the high side PWM signal produced by the three-phase timing unit over half the PWM pe- riod. The switching signals produced by the three-phase timing unit are also adjusted to incorporate the programmed dead time value in the PWMDT register. The three-phase timing unit produces active LO signals so that a LO level corresponds to a command to turn on the associated power device. A typical pair of PWM outputs (in this case for AH and AL) from the timing unit are shown in Figure 22 for operation in single update mode. All illustrated time values indicate the integer value in the associated register and can be converted to time by simply multiplying by the fundamental time increment, tCK. First, it is noted that the switching patterns are symmetrical about the midpoint of the switching period in this single up- date mode since the same values of PWMCHA, PWMTM and PWMDT are used to define the signals in both half cycles of the period. It can be seen how the programmed duty cycles are adjusted to incorporate the desired dead time into the resultant pair of PWM signals. Clearly, the dead time is incorporated by moving the switching instants of both PWM signals (AH and AL) away from the instant set by the PWMCHA register. Both switching edges are moved by an equal amount (PWMDT × tCK) to preserve the symmetrical output patterns. Also shown is the PWMSYNC pulse whose width is set by the PWMSYNCWT register and Bit 3 of the SYSSTAT register, which indicates whether operation is in the first or second half cycle of the PWM period. PWMSYNC AH AL PWMCHA PWMCHA 2 PWMDT PWMSYNCWT + 1 2 PWMDT SYSSTAT (3) PWMTM PWMTM Figure 22. Typical PWM Outputs of Three-Phase Timing Unit in Single Update Mode (Active LO Waveforms) The resultant on-times of the PWM signals over the full PWM period (two half periods) produced by the PWM timing unit, and illustrated in Figure 22, may be written as: T PWMCHA PWMDT t AH CK =× ()× 2– T PWMTM PWMCHA PWMDT t AL CK =× ()× 2– – and the corresponding duty cycles are: d T T PWMCHA PWMDT PWMTM AH AH S == – d T T PWMTM PWMCHA PWMDT PWMTM AL AL S == –– Obviously negative values of TAH and TAL are not permitted and the minimum permissible value is zero, corresponding to a 0% duty cycle. In a similar fashion, the maximum value is TS, corre- sponding to a 100% duty cycle. The output signals from the timing unit for operation in double update mode are shown in Figure 23. This illustrates a com- pletely general case where the switching frequency, dead time and duty cycle are all changed in the second half of the PWM period. Of course, the same value for any or all of these quanti- ties could be used in both halves of the PWM cycle. However, it can be seen that there is no guarantee that symmetrical PWM signals will be produced by the timing unit in this double update mode. Additionally, it is seen that the dead time is inserted into the PWM signals in the same way as in the single update mode. PWMCHA2 2 PWMDT1 2 PWMDT2 PWMSYNCWT2 + 1 PWMCHA1 PWMTM1 PWMTM2 PWMSYNCWT1 + 1 AH AL PWMSYNC SYSSTAT (3) Figure 23. Typical PWM Outputs of Three-Phase Timing Unit in Double Update Mode (Active LO Waveforms) In general the on-times of the PWM signals over the full PWM period in double update mode can be defined as: T PWMCHA PWMCHA PWMDT PWMDT t AH CK =+ () × 12 1 2 –– T PWMTM PWMTM PWMCHA PWMCHA PWMDT PWMDT t AL CK =+ ( ) × 12 1 2 1 2 –– – – where the subscript 1 refers to the value of that register during the first half cycle and the subscript 2 refers to the value during the second half cycle. The corresponding duty cycles are: d T T PWMCHA PWMCHA PWMDT PWMDT PWMTM PWMTM AH AH S == + + 12 1 2 12 –– d T T PWMTM PWMTM PWMCHA PWMCHA PWMDT PWMDT PWMTM PWMTM AL AL S == ++ + 1 212 1 2 12 –– – since for the completely general case in double update mode, the switching period is given by: T PWMTM PWMTM t SCK =+ () × 12 Again, the values of TAH and TAL are constrained to lie between zero and TS. Similar PWM signals to those illustrated in Figure 22 and Figure 23 can be produced on the BH, BL, CH and CL outputs by programming the PWMCHB and PWMCHC registers in a manner identical to that described for PWMCHA. Special Consideration for PWM Operation in Overmodulation The PWM Timing Unit is capable of producing PWM signals with variable duty cycle values at the PWM output pins. At the extremities of the modulation process, both 0% and 100% modulation are possible. These two modes are termed full OFF and full ON respectively. In between, for other duty cycle val- ues, the operation is termed normal modulation. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |