| Electronic Components Datasheet Search |
|
FT122 Datasheet(PDF) 20 Page - Future Technology Devices International Ltd. |
|
|
|||||||||||||||||||||||||||||
FT122 Datasheet(HTML) 20 Page - Future Technology Devices International Ltd. |
|
20 / 47 page ![]() Copyright © 2014 Future Technology Devices International Limited 20 Document No.: FT_000647 FT122 ENHANCED USB DEVICE CONTROLLER WITH PARALLEL BUS IC Datasheet Version 1.1 Clearance No.: FTDI# 313 Bit Symbol Reset Description 1: CLKOUT remains unchanged during USB suspend Note: The programmed value will not be changed by a bus reset. 2 Clock Running 1 0: internal clocks stop during USB suspend 1: internal clocks continue running during USB suspend This bit must be set to ‘0’ for bus powered application in order to meet the USB suspend current requirement. Note: The programmed value will not be changed by a bus reset. 3 Interrupt Mode 1 0: interrupt will not generate on NAK or Error transactions 1: interrupt will generate on NAK and Error transactions Note: The programmed value will not be changed by a bus reset. 4 DP_Pullup 0 0: Pullup resistor on DP pin disabled 1: Pullup resistor on DP pin enabled when Vbus is present Note: The programmed value will not be changed by a bus reset. 5 Reserved 0 Reserved, write to 0 7-6 Endpoint Configuration Mode 0b’00 Set the endpoint configuration mode for EP2. 00: Mode 0 (Non-ISO Mode) 01: Mode 1 (ISO-OUT Mode) 10: Mode 2 (ISO-IN Mode) 11: Mode 3 (ISO-IO Mode) In Enhanced Mode, these 2 bits are reserved. The Endpoint Configuration will be done through separate command. See “Set Endpoint Configuration” commands. Table 6-5 Configuration Register (Byte 1) Bit Symbol Reset Description 3-0 Clock Division Factor 0b’1011 The Clock Division Factor value (CDF) determines the output clock frequency on the CLKOUT pin. Frequency = 48 MHz / (CDF +1), where CDF ranges 1-12 or the allowed CLKOUT frequency is 4-24 MHz. Default CLKOUT is 4 MHz. When the CDF is programmed to 0b’1111, the CLKOUT will be turned off. It is recommended to turn off the CLKOUT if it is not used, for power saving (about 3mA). Note: The programmed value will not be changed by a bus reset. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |