27 / 56 page ![]() Philips Semiconductors Product specification SC28L198 Octal UART for 3.3V and 5V supply voltage 1999 Jan 14 27 Table 22. XISR – Xon–Xoff Interrupt Status Register Bits 7:6 Bits 5:4 Bits 3:2 Bits 1:0 Received X Character Sta- tus Automatic X Character transmis- sion status TxD flow status TxD character status 00 – none 01 – Xoff received 10 – Xon received 11 – both received 00 – none 01 – Xon transmitted 10 – Xoff transmitted 11 – Illegal, does not occur 00 – normal 01 – TxD halt pending 10 – re–enabled 11 – flow disabled 00 – normal TxD data 01 – wait on normal data 10 – Xoff in pending 11 – Xon in pending XISR[7:6] – Received X Character Status. This field can be read to determine if the receiver has encountered an Xon or Xoff character in the incoming data stream. These bits are maintained until a read of the XISR. The field is updated by X character reception regardless of the state of MR0(7, 3:2) or IMR(4). The field can therefore be used as a character detector for the bit patterns stored in the Xon and Xoff Character Registers. XISR[5:4] – Automatic transmission Status. This field indicates the last flow control character sent in the Auto Receiver flow control mode. If Auto Receiver mode has not been enabled, this field will always read b’00. It will likewise reset to b’00 if MR0(3) is reset. If the Auto Receiver mode is exited while this field reads b’10, it is the user’s responsibility to transmit an Xon, when appropriate. XISR[3:2] – TxD flow Status. This field tracks the transmitter’s flow status as follows: 00 – normal. The flow control is under host control. 01 – TxD halt pending. After the current character finishes the transmitter will stop. The status will then change to b’00. 10 – re–enabled. The transmitter had been halted and restarted. It is sending data characters. After a read of the XISR, it will return to ”normal” status. 11 – disabled. The transmitter is flow controlled. XISR[1:0] – TxD character Status. This field allows determination of the type of character being transmitted. If XISR(1:0) is b’01, the channel is waiting for a data character to transfer from the TxFIFO. This condition will only occur for a bit time after an Xon or Xoff character transmission unless the TxFIFO is empty. Table 23. WDTRCR – Watch-dog Timer Enable Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 WDT h WDT g WDT f WDT e WDT d WDT c WDT b WDT a 1 on 0 off 1 on 0 off 1 on 0 off 1 on 0 off 1 on 0 off 1 on 0 off 1 on 0 off 1 on 0 off This register enables the watch-dog Timer for each of the 8 receivers on the Octal UART. Table 24. BRGTRU – BRG Timer Reload Registers, Upper Bits 7:0 8 MSB of the BRG Timer divisor. This is the upper byte of the 16 bit value used by the BRG timer in generating a baud rate clock Table 25. BRGTRL – BRG Timer Reload Registers, Lower Bits 7:0 8 LSB of the BRG Timer divisor. This is the lower byte of the 16 bit value used by the BRG timer in generating a baud rate clock. Table 26. BRGTCR – BRG Timer Control Register (BRGTCR) Bit 7 Bit 6:4 Bit 3 Bit 2:0 BRGTCR b, Register control BRGTCR b, Clock selection BRGTCR a, Register control BRGTCR a, Clock selection 0 – Resets the timer register and holds it stopped 1 – Allows the timer register to run. 000 – Sclk / 16 001 – Sclk / 32 010 – Sclk/ 64 011 – Sclk / 128 100 – X1 101 – X1 / 2 110 – I/O1b 111 – GIN(1) 0 – Resets the timer register and holds it stopped. 1 – Allows the timer register to run. 000 – Sclk / 16 001 – Sclk / 32 010 – Sclk / 64 011 – Sclk / 128 100 – X1 101 – X1 / 2 110 – I/O1a 111 – GIN(0) Start/Stop control and clock select register for the two BRG counters. The clock selection is for the input to the counters. It is that clock divided by the number represented by the BRGTU and BRGTL the will be used as the 16x clock for the receivers and transmitters. When the BRG timer Clock is selected for the receiver(s) or transmitter(s) the receivers and transmitters will consider it as a 16x clock and further device it by 16. In other words the receivers and transmitters will always be in the 16x ode of operation when the internal BRG timer is selected for their clock. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |