43 / 69 page ![]() ADV7192 –43– REV. 0 GAMMA CORRECTION REGISTERS 0–13 (GAMMA CORRECTION 0–13) (Address (SR5–SR0) = 26H–32H) The Gamma Correction Registers are fourteen 8-bit wide regis- ter. They are used to program the gamma correction Curves A and B. Generally gamma correction is applied to compensate for the nonlinear relationship between signal input and brightness level output (as perceived on the CRT). It can also be applied wher- ever nonlinear processing is used. Gamma correction uses the function: SignalOUT = (SignalIN)γ where γ = gamma power factor Gamma correction is performed on the luma data only. The user has the choice to use two different curves, Curve A or Curve B. At any one time only one of these curves can be used. The response of the curve is programmed at seven predefined locations. In changing the values at these locations the gamma curve can be modified. Between these points linear interpolation is used to generate intermediate values. Considering the curve to have a total length of 256 points, the seven locations are at: 32, 64, 96, 128, 160, 192, and 224. Location 0, 16, 240 and 255 are fixed and can not be changed. For the length of 16 to 240 the gamma correction curve has to be calculated as below: y = xγ where y = gamma corrected output x = linear input signal γ = gamma power factor To program the gamma correction registers, the seven values for y have to be calculated using the following formula: yn = [x(n–16) /(240–16) ]γ × (240–16) + 16 where x(n-16) = Value for x along x-axis at points n = 32, 64, 96, 128, 160, 192, or 224 yn = Value for y along the y-axis, which has to be written into the gamma correction register Example: y32 = [(16/224)0.5 × 224] + 16 = 76* y64 = [(48/224)0.5 × 224] + 16 = 120* y96 = [(80/224)0.5 × 224] + 16 = 150* y128 = [(112/224)0.5 × 224] + 16 = 174* *Rounded to the nearest integer. The above will result in a gamma curve shown below, assuming a ramp signal as an input. 250 200 150 100 50 0 300 250 200 150 100 50 300 SIGNAL OUTPUT SIGNAL INPUT 0.5 GAMMA CORRECTION BLOCK OUTPUT TO A RAMP INPUT 0 50 100 150 200 250 LOCATION Figure 92. Signal Input (Ramp) and Signal Output for Gamma 0.5 250 200 150 100 50 0 300 SIGNAL OUTPUTS SIGNAL INPUT 0.5 GAMMA CORRECTION BLOCK OUTPUT TO A RAMP INPUT FOR VARIOUS GAMMA VALUES 0 50 100 150 200 250 LOCATION 0.3 1.5 1.8 Figure 93. Signal Input (Ramp) and Selectable Gamma Output Curves The gamma curves shown above are examples only, any user defined curve is acceptable in the range of 16–240. DNR27 DNR26 DNR25 DNR24 DNR23 DNR22 DNR21 DNR20 BLOCK OFFSET CONTROL DNR DNR DNR DNR 27 26 25 24 0000 0 PIXEL OFFSET 0001 1 PIXEL OFFSET 0010 2 PIXEL OFFSET •••• • •••• • •••• • 1101 13 PIXEL OFFSET 1110 14 PIXEL OFFSET 1111 15 PIXEL OFFSET DNR INPUT SELECT CONTROL DNR DNR DNR 22 21 20 0 0 1 FILTER A 0 1 0 FILTER B 0 1 1 FILTER C 1 0 0 FILTER D 0 DNR MODE 1 DNR SHARPNESS MODE DNR23 DNR MODE CONTROL Figure 91. DNR Register 2 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |