57 / 92 page ![]() 16.0 Registers (Continued) 16.7 LIMIT REGISTERS 16.7.1 Registers 78–7Fh Temperature Limit Registers Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 78h R/W Processor 1 (Zone1) Low Temp 76543210 80h 79h R/W Processor 1 (Zone1) High Temp 76543210 80h 7Ah R/W Processor 2 (Zone2) Low Temp 76543210 80h 7Bh R/W Processor 2 (Zone2) High Temp 76543210 80h 7Ch R/W Internal (Zone3) Low Temp 76543210 80h 7Dh R/W Internal (Zone3) High Temp 76543210 80h 7Eh R/W External Digital (Zone4) Low Temp 76543210 80h 7Fh R/W External Digital (Zone4) High Temp 76543210 80h If an external temperature input or the internal temperature sensor either exceeds the value set in the high limit register or falls below the value set in the low limit register, the corresponding bit in the B_ and H_Error Status 1 register is set automatically by the LM93. For example, if the temperature read from the Remote1− and Remote1+ inputs exceeds the Processor (Zone1) High Temp register limit setting, the ZN1_ERR bit in both B_Error Status 1 and H_Error Status 1 registers is set. The temperature limits in these registers is represented as 8 bit, 2’s complement, signed numbers in Celsius. If any high temp limit register is set to 80h then the B_ and H_Error Status register bit for that temperature channel is masked. 16.7.2 Registers 80–83h Fan Boost Temperature Registers Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 80h R/W Fan Boost Temp Zone 1 76543210 3Ch 81h R/W Fan Boost Temp Zone 2 76543210 3Ch 82h R/W Fan Boost Temp Zone 3 76543210 23h 83h R/W Fan Boost Temp Zone 4 76543210 23h If any thermal zone exceeds the temperature set in the Fan Boost Limit register, both of the PWM outputs are set to 100%. The fan boost function takes precedence over manual override. This is a safety feature that attempts to cool the system if there is a potentially catastrophic thermal event. If set to 7Fh and the fan control temperature resolution is 1˚C, the feature is disabled. Default = 60˚C = 3Ch for zones 1 and 2 Default = 35˚C = 23h for zones 3 and 4 The temperature has to fall the number of degrees specified in the Fan Boost Hysteresis registers, below this temperature to cause the PWM outputs to return to normal operation. www.national.com 57 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |