13 / 52 page ![]() PRELIMINARY DATA SHEET MAS 3506D Micronas 13 3. Controlling 3.1. I2C-Access Communication between the MAS 3506D and the external controller is done via an I2C slave interface. 3.1.1. Device Address The device addresses are 3ahex for writing (DW) and 3bhex for reading (DR), respectively. I 2C clock syn- chronization is used to slow down the bus if required. 3.1.2. I2C Registers and Subaddresses The interface uses one level of subaddresses. The MAS 3506D interface has 3 subaddresses allocated for the corresponding I2C-registers. The address 6ahex is used for basic control, i.e. reset and task select. The other addresses are used for data transfer from/to the MAS 3506D. The I2C-control and data registers of the MAS 3506D are 16 bits wide, the MSB is denoted as bit [15]. Trans- missions via I2C-bus have to take place in 16-bit words (two byte transfers, MSB sent first); thus for each reg- ister access two 8-bit data words must be sent/ received via I2C-bus. 3.1.3. Conventions for the Command Description The description of the various controller commands uses the following formalism: – Abbreviations used in the following descriptions: a address d data value n count value o offset value r register number x don’t care – Memory addresses like D1:89f are always in hexa- decimal notation. – A data value is split into 4-bit nibbles which are numbered beginning with 0 for the least significant nibble. – Data values in nibbles are always shown in hexa- decimal notation. – A hexadecimal 20-bit number d is written, e.g. as d = 17c63hex, its five nibbles are d0 = 3hex, d1 = 6hex, d2 = chex, d3 = 7hex, and d4 = 1hex. – Variables used in the following descriptions: DW 3ahex I2C-device write DR 3bhex I2C-device read data_write 68hex data register write data_read 69hex data register read control 6ahex control register write – Bus signals SStart PStop A ACK = Acknowledge N NAK = Not acknowledge W Wait = a wait time ( ≤ 4 ms) may occur – Symbols in the telegram examples < Start condition > Stop dd data byte xx ignore All telegram digits are hexadecimal, data originating from the MAS 3506D are grayed. Example: <3a 68 dd dd> write data to DSP <3a 69 <3b dd dd > read data from DSP Figure 3–1 shows I2C bus protocols for read and write operations of the interface; the read operation requires an extra start condition and repetition of the I2C-device address with the read command (DR). Fields with sig- nals/data originating from the MAS 3506D are marked by a gray background. Note that in some cases the data reading process must be concluded by a NAK condition. The MAS 3506D firmware scans the I2C interface peri- odically and checks for pending or new commands. Table 3–1: I2C device address bits A6 A5 A4 A3 A2 A1 A0 write/ read 001 11010/1 Table 3–2: I2C subaddresses Sub- address I2C- Register Function 68hex data_write Controller writes to MAS 3506D data register 69hex data_read Controller reads from MAS 3506D data register 6ahex control Controller writes to MAS 3506D control register |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |