Electronic Components Datasheet Search
  English  ▼

X  

TAS2764 Datasheet(PDF) 29 Page - Texas Instruments

Click here to check the latest version.
Part # TAS2764
Description  TAS2764 Digital Input Mono Class-D Audio Amplifier With Speaker IV Sense
PDF  107 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI [Texas Instruments]
Direct Link  http://www.ti.com
Logo TI - Texas Instruments

TAS2764 Datasheet(HTML) 29 Page - Texas Instruments

Back Button TAS2764 Datasheet HTML 25Page - Texas Instruments TAS2764 Datasheet HTML 26Page - Texas Instruments TAS2764 Datasheet HTML 27Page - Texas Instruments TAS2764 Datasheet HTML 28Page - Texas Instruments TAS2764 Datasheet HTML 29Page - Texas Instruments TAS2764 Datasheet HTML 30Page - Texas Instruments TAS2764 Datasheet HTML 31Page - Texas Instruments TAS2764 Datasheet HTML 32Page - Texas Instruments TAS2764 Datasheet HTML 33Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 29 / 107 page
background image
8.5 Operational Modes
8.5.1 Hardware Shutdown
The device enters Hardware Shutdown mode if the SDZ pin is asserted low. In Hardware Shutdown mode, the
device consumes the minimum quiescent current from AVDD, VBAT1S and PVDD supplies. All registers loose
state in this mode and I2C communication is disabled.
In normal shutdown mode if SDZ is asserted low while audio is playing, the device will ramp down volume on the
audio, stop the Class-D switching, power down analog and digital blocks and finally put the device into Hardware
Shutdown mode. If configured in normal shutdown mode with timeout the device will force a hard shutdown after
a timeout set by the configurable shutdown timer (register bits SDZ_TIMEOUT[1:0]). The device can also be
configured for forced hard shutdown and in this case it will not attempt to gracefully disable the audio channel.
The shutdown mode can be controlled using SDZ_MODE[1:0] register bits.
When SDZ is released, the device will sample the ADDR pin and enter the software shutdown mode.
8.5.2 Mode Control and Software Reset
The TAS2764 mode can be configured by writing the MODE[2:0] register bits.
A software reset can be accomplished by setting high the SW_RESET register bit. This bit is self clearing. Once
enabled it will restore all registers to their default values.
8.5.3 Software Shutdown
Software Shutdown mode powers down all analog blocks required to playback audio, but does not cause the
device to loose register state.
The registers are available through I2C interface.
Software Shutdown is enabled by asserting the MODE[2:0] register bits to 3'b010. If audio is playing when
Software Shutdown is asserted, the Class-D will volume ramp down before shutting down. When de-asserted,
the Class-D will begin switching and volume ramp back to the programmed digital volume setting.
8.5.4 Mute
The TAS2764 will ramp down volume of the Class-D amplifier to a mute state by setting the MODE[2:0] register
bits to 3'b001. During mute the Class-D still switches but transmits no audio content. If mute is de-asserted, the
device will ramp back the volume to the programmed digital setting.
8.5.5 Active
In Active Mode the Class-D switches and plays back audio. Speaker voltage and current sensing are operational
if enabled. PDM inputs are also active if enabled. Set the MODE[2:0] register bits to 3'b000 to enter active mode.
8.5.6 Diagnostic
The TAS2764 has a diagnostic generator that can be used without any PCM clocking to the device. If DG_CLK
register bit is set low, an internal oscillator is used to generate the test patterns selected by DG_SIG[4:0] register
bits. For sine-wave generation the sampling frequency fs should be first set using the SAMP_RATE[2:0] register
bits.
The programable DC level for diagnostic mode can be set using the DG_DC[31:0] register bits.
To play a DC diagnostic tone set the bits HPF_FREQ_PB[2:0] in register 0x04 to 0h (disabled DC blocker).
8.5.7 Noise Gate
In this mode of operation described in section Section 8.4.2.7 the TAS2764 monitors the signal and powers
down the class-D when signal goes below a threshold.
8.6 Faults and Status
During the power-up sequence, the circuit monitoring the AVDD pin (UVLO) will hold the device in reset
(including all configuration registers) until the supply is valid. The device will not exit hardware shutdown until
www.ti.com
TAS2764
SLOS998 – DECEMBER 2020
Copyright © 2020 Texas Instruments Incorporated
Submit Document Feedback
29
Product Folder Links: TAS2764



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com