78 / 145 page ![]() 6.3.2 VINLOW monitoring control register (VINLOW_CR) Table 43. VINLOW_CR 7 6 5 4 3 2 1 0 reserved reserved VINLOW_HYST[1:0] VINLOW_RISE[2:0] VINLOW_EN R R R/W R/W R/W R/W R/W R/W • Address: 0x11 • Default: 0x00 • Description: VINLOW monitoring control register (see Section 5.4.1 ). This register is initialized to the default value in the CHECK&LOAD state. [7:6] reserved [5:4] VINLOW_HYST[1:0]: VINLOW threshold hysteresis 00: 100 mV 01: 200 mV 10: 300 mV 11: 400 mV [3:1] VINLOW_RISE[2:0]: VINLOW_Rise threshold = 000: VINOK_Fall + 50 mV 001: VINOK_Fall + 100 mV 010: VINOK_Fall + 150 mV 011: VINOK_Fall + 200 mV 100: VINOK_Fall + 250 mV 101: VINOK_Fall + 300 mV 110: VINOK_Fall + 350 mV 111: VINOK_Fall + 400 mV [0] VINLOW_EN: VINLOW monitoring enable bit 0: VINLOW monitoring is disabled 1: VINLOW monitoring is enabled STPMIC25 Register descriptions DS14278 - Rev 3 page 78/145 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|