| Electronic Components Datasheet Search |
|
TSC2014IYZGR Datasheet(PDF) 21 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TSC2014IYZGR Datasheet(HTML) 21 Page - Texas Instruments |
|
21 / 62 page ![]() N Acquired Data W N N m asu e rementsinput intotemporaryarray Sortby descendingorder Averagingoutp t u fromwindowW N M=1 M>1andW=1 M N Median value fromarrayM N M>1andW>1 Averagingoutp t u fromwindowW M W 21 TSC2014 www.ti.com SBAS484B – SEPTEMBER 2010 – REVISED DECEMBER 2016 Product Folder Links: TSC2014 Submit Documentation Feedback Copyright © 2010–2016, Texas Instruments Incorporated NOTE The default setting for MAVF is MVF (median value filter with averaging bypassed) for any invalid configuration. For example, if (M1, M0, W1, W0) = (1,0,1,0), the MAVF performs as it was configured for (1,0,0,0), median filter only with filter size = 7 and no averaging. The only exception is M > 1 and (W1, W0) = (1,1). This setting is reserved and should not be used. Table 3. Combined MAV Filter Setting M W INTERPRETATION N = OUTPUT = 1 = 1 Bypass both MAF and AVF W The converted result = 1 > 1 Bypass MVF only W Average of W converted results > 1 = 1 Bypass AVF only M Median of M converted results > 1 > 1 M > W M Average of middle W of M converted results with the median counted twice The MAV filter is available for all analog inputs including the touch screen inputs, temperature measurements TEMP1 and TEMP2, and the AUX measurement. Figure 22. MAV Filter Operation (patent pending) 7.3.4.7 Zone Detection The Zone Detection unit is capable of screening all processed data from the MAVF and retaining only the data of interest (data that fit the prerequisite). This unit can be programmed to send an alert if a predefined condition set by two threshold value registers is met. Three different zones may be set: 1. Above the upper limit (X ≥ Threshold High) 2. Between the two thresholds (Threshold Low < X < Threshold High) 3. Below the lower limit (X ≤ Threshold Low) The AUX and temperatures TEMP1 and TEMP2 have separate threshold value registers that can be enabled or disabled. This function is not available to the touch screen inputs. Once the preset condition is met, the DAV output to the PINTDAV pin is pulled low and the corresponding DAV bit is set. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |