| Electronic Components Datasheet Search |
|
TSC2014IYZGR Datasheet(PDF) 39 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TSC2014IYZGR Datasheet(HTML) 39 Page - Texas Instruments |
|
39 / 62 page ![]() 39 TSC2014 www.ti.com SBAS484B – SEPTEMBER 2010 – REVISED DECEMBER 2016 Product Folder Links: TSC2014 Submit Documentation Feedback Copyright © 2010–2016, Texas Instruments Incorporated 7.6.3 Control Byte 1 Figure 38. Control Byte Format: Start a Conversion and Mode Setting MSB D7 D6 D5 D4 D3 D2 D1 LSB D0 (Control Byte 1) C3 C2 C1 C0 RM SWRST STS LEGEND: R/W = Read/Write; R = Read only; -n = value after reset Table 8. Control Byte 1 Bit Register Description (D7 = 1) Bit Field Type Reset Description D7 Control Byte ID R/W 0000h 1: Control Byte 1 (start conversion and channel select and conversion-related configuration). 0: Control Byte 0 (read/write data registers and non-conversion- related controls). D6 C3 R 0000h Converter function select bits. These bits select the input to be converted, and the converter function to be executed. Table 9 lists the possible converter functions. D5 C2 R 0000h D4 C1 R 0000h D3 C0 R 0000h D2 RM R/W 0000h 0: 10 Bit 1: 12 Bit D1 SWRST R/W 0000h Software Reset. This bit is self-clearing. 1: Reset all register values to default D0 STS R/W 0000h Stop bit for all converter functions. This bit is self-clearing. Table 9. Converter Function Select C3 C2 C1 C0 FUNCTION 0 0 0 0 Touch screen scan function: X, Y, Z1, and Z2 coordinates converted and the results returned to X, Y, Z1, and Z2 data registers. Scan continues until either the pen is lifted or a stop bit is sent. 0 0 0 1 Touch screen scan function: X and Y coordinates converted and the results returned to X and Y data registers. Scan continues until either the pen is lifted or a stop bit is sent. 0 0 1 0 Touch screen scan function: X coordinate converted and the results returned to X data register. 0 0 1 1 Touch screen scan function: Y coordinate converted and the results returned to Y data register. 0 1 0 0 Touch screen scan function: Z1 and Z2 coordinates converted and the results returned to Z1 and Z2 data registers. 0 1 0 1 Auxiliary input converted and the results returned to the AUX data register. 0 1 1 0 A temperature measurement is made and the results returned to the Temperature Measurement 1 data register. 0 1 1 1 A differential temperature measurement is made and the results returned to the Temperature Measurement 2 data register. 1 0 0 0 Auxiliary input is converted continuously and the results returned to the AUX data register. 1 0 0 1 Touch screen panel connection to X-axis drivers is tested. The test result is output to PINTDAV and shown in STATUS register. 1 0 1 0 Touch screen panel connection to Y-axis drivers is tested. The test result is output to PINTDAV and shown in STATUS register. 1 0 1 1 RESERVED (Note: any condition caused by this command can be cleared by setting the STS bit to 1). 1 1 0 0 Touch screen panel short-circuit (between X and Y plates) is tested through Y-axis. The test result is output to PINTDAV and shown in the STATUS register. 1 1 0 1 X+, X– drivers status 1 1 1 0 Y+, Y– drivers status 1 1 1 1 Y+, X– drivers status |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |