| Electronic Components Datasheet Search |
|
LM64 Datasheet(PDF) 13 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
LM64 Datasheet(HTML) 13 Page - Texas Instruments |
|
13 / 42 page ![]() Remote High Limit RDTS Measurement LM64 ALERT Pin Status Register: RTDS High TIME Figure 6-2. ALERT Output as Temperature Comparator Response Diagram 6.3.2.2 ALERT Output as an Interrupt The LM64's ALERT output can be implemented as a simple interrupt signal when it is used to trigger an interrupt service routine. In such systems it is desirable for the interrupt flag to repeatedly trigger during or before the interrupt service routine has been completed. Under this method of operation, during the read of the ALERT Status Register the LM64 will set the ALERT Mask bit in the Configuration Register if any bit in the ALERT Status Register is set, with the exception of Busy and Open. This prevents further ALERT triggering until the master has reset the ALERT Mask bit, at the end of the interrupt service routine. The ALERT Status Register bits are cleared only upon a read command from the master (see Figure 6-2) and will be re-asserted at the end of the next conversion if the triggering condition(s) persist(s). In order for the ALERT to be used as a dedicated interrupt signal, the Comparator Mode bit in the Remote Diode Temperature Filter and Comparator Mode Register must be set low. This is the power-on default state. The following sequence describes the response of a system that uses the ALERT output pin as an interrupt flag: 1. Master senses ALERT low. 2. Master reads the LM64 ALERT Status Register to determine what caused the ALERT. 3. LM64 clears ALERT Status Register, resets the ALERT HIGH and sets the ALERT Mask bit in the Configuration Register. 4. Master attends to conditions that caused the ALERT to be triggered. The fan is started, setpoint limits are adjusted, etc. 5. Master resets the ALERT Mask bit in the Configuration Register. Remote High Limit RDTS Measurement TIME ALERT mask set in response to reading of status register by master LM64 ALERT pin Status Register: RTDS High End of Temperature conversion Figure 6-3. ALERT Output as an Interrupt Temperature Response Diagram 6.3.2.3 ALERT Output as an SMBus ALERT An SMBus alert line is created when the ALERT output is connected to: (1) one or more ALERT outputs of other SMBus compatible devices, and (2) to a master. Under this implementation, the LM64's ALERT should be operated using the ARA (Alert Response Address) protocol. The SMBus 2.0 ARA protocol, defined in the SMBus specification 2.0, is a procedure designed to assist the master in determining which part generated an interrupt and to service that interrupt. www.ti.com LM64 SNAS207B – MAY 2004 – REVISED JANUARY 2024 Copyright © 2024 Texas Instruments Incorporated Submit Document Feedback 13 Product Folder Links: LM64 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |