18 / 102 page ![]() NXP Semiconductors PCF85263A Tiny RTC/Calendar with Alarm Function, Battery Switch-Over, Time Stamp Input, and I2C-bus • Write data (clear STOP, 00h). Time starts counting from this point • I2C STOP condition 7.3 Stop-watch mode time registers These registers are coded in the BCD format to simplify application use. Stop-watch mode is enabled by setting RTCM = 1. In stop-watch mode, the PCF85263A counts from 100th seconds to 99 9 999 hours. There are no day, weekday, month, or year registers. The default state is: Time: 00 00 00:00:00.00 Monitor bits: OS = 1, EMON = 0 (for details, see Section 7.2.2 and Section 7.2.3) Bit positions labeled as - are not implemented and return 0 when read. Upper-digit (ten’s place) Digit (unit place) Address Register name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 00h 100th_seconds [1] 0 to 9 0 to 9 01h Seconds OS 0 to 5 0 to 9 02h Minutes EMON 0 to 5 0 to 9 03h Hours_xx_xx_00 0 to 9 0 to 9 04h Hours_xx_00_xx 0 to 9 0 to 9 05h Hours_00_xx_xx 0 to 9 0 to 9 06h Not used - - - - - - - - 07h Not used - - - - - - - - Table 11. Time registers in stop-watch mode (RTCM = 1) [1] The 100th_seconds register is only available when the 100TH mode is enabled. For details, see Section 7.13.1. When the 100TH mode is disabled, this register always returns 0. 7.3.1 Setting and reading the time in stop-watch mode Figure 12 shows the data flow and data dependencies starting from the 100 Hz clock tick. During read operations, the time counting circuits (memory locations 00h through 07h) are copied into an output register. The RTC continues counting in the background. When reading or writing the time, it is important to make a read or write access in one go, that is, setting or reading 100th_seconds through to HR_00_xx_xx must be made in one single access. Failing to comply with this method could result in the time becoming corrupted. As an example, if the seconds value is set in one access and then in a following access the minutes value is set, it is possible that the time increments between the two accesses. A similar problem exists when reading. A roll-over can occur between reads. therefore giving the seconds from one moment and the minutes from the next. PCF85263A All information provided in this document is subject to legal disclaimers. © 2025 NXP B.V. All rights reserved. Product data sheet Rev. 5.4 — 12 December 2025 Document feedback 18 / 102 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |