| Electronic Components Datasheet Search |
|
ML7344J Datasheet(PDF) 43 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
ML7344J Datasheet(HTML) 43 Page - List of Unclassifed Manufacturers |
|
43 / 151 page ![]() FEDL7344C/E/J-04 ML7344C/E/J 43/151 ●Field check function ML7344 has the function of comparing the 9 bytes following L-field (Format A/B: start from C-field, Format C: start from Data-field) in a receiving packet. Based on comparison with the expected data, possible to generate interrupts (Field check function). Field check can be possible with the following register setting. When using this function, RXDIO_CTRL [1:0] ([DIO_SET:B0 0x0C(7-6)]) = 0b00 (FIFO mode) or 0b11 (data output mode 2) setting is required. Function Register RX data process setting when Field check unmatched [C_CHECK_CTRL: B0 0x1B(7)] Field check interrupt setting [C_CHECK_CTRL: B0 0x1B(6)] C-field detection enable setting [C_CHECK_CTRL: B0 0x1B(4-0)] M-field detection enable setting [M_CHECK_CTRL: B0 0x1C(3-0)] A-field detection enable setting [A_CHECK_CTRL: B0 0x1D(5-0)] C-field code setting [C_FIELD_CODE1: B0 0x1E] [C_FIELD_CODE2: B0 0x1F] [C_FIELD_CODE3: B0 0x20] [C_FIELD_CODE4: B0 0x21] [C_FIELD_CODE5: B0 0x22] M-field code setting [M_FIELD_CODE1: B0 0x23] [M_FIELD_CODE2: B0 0x24] [M_FIELD_CODE3: B0 0x25] [M_FIELD_CODE4: B0 0x26] A-field code setting [A_FIELD_CODE1: B0 0x27] [A_FIELD_CODE2: B0 0x28] [A_FIELD_CODE3: B0 0x29] [A_FIELD_CODE4: B0 0x2A] [A_FIELD_CODE5: B0 0x2B] [A_FIELD_CODE6: B0 0x2C] The following describes the relation between each comparison code and incoming RX data. [Format A/B(Wireless M-Bus)] Field check can be controlled by setting disabled/enabled for each comparison code (1 byte). If all specified Field data (C-field/M-field/A-field) are matched, Field checking matching will be notified. However, if C-field data and C_FIELD_CODE5 are matched, even if other Field data (M-field/A-field) are not matched, Field check result will be notified as ”match”. MSB Preamble Sync Word L field 1st Block A field C field M field 1 byte 1 byte 2 bytes 10/18/ 32bits Over n*2 bit 6 bytes CRC field 0/2 bytes C1: [C_FIELD_CODE1: B0 0x1E] C2: [C_FIELD_CODE2: B0 0x1F] C3: [C_FIELD_CODE3: B0 0x20] C4: [C_FIELD_CODE4: B0 0x21] C5: [C_FIELD_CODE5: B0 0x22] A1. [A_FIELD_CODE1: B0 0x27] A2. [A_FIELD_CODE2: B0 0x28] A3. [A_FIELD_CODE3: B0 0x29] A4. [A_FIELD_CODE4: B0 0x2A] A5. [A_FIELD_CODE5: B0 0x2B] A6. [A_FIELD_CODE6: B0 0x2C] A1 A2 A3 A4 A5 A6 LSB M1. [M_FIELD_CODE1: B0 0x23] M2. [M_FIELD_CODE2: B0 0x24] M3. [M_FIELD_CODE3: B0 0x25] M4. [M_FIELD_CODE4: B0 0x26] M1 M2 M3 M4 C1 C2 C3 C4 C5 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |