Back Button AD9175 Datasheet HTML 54Page - Analog Devices AD9175 Datasheet HTML 55Page - Analog Devices AD9175 Datasheet HTML 56Page - Analog Devices AD9175 Datasheet HTML 57Page - Analog Devices AD9175 Datasheet HTML 58Page - Analog Devices AD9175 Datasheet HTML 59Page - Analog Devices AD9175 Datasheet HTML 60Page - Analog Devices AD9175 Datasheet HTML 61Page - Analog Devices AD9175 Datasheet HTML 62Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 58 / 150 page
background image
AD9175
Data Sheet
Rev. A | Page 58 of 150
Table 46. Main Datapath NCO FTW Registers
Address
Value
Description
0x114
DDSM_FTW[7:0]
8 LSBs of FTW
0x115
DDSM_FTW[15:8]
Next 8 bits of FTW
0x116
DDSM_FTW[23:16]
Next 8 bits of FTW
0x117
DDSM_FTW[31:24]
Next 8 bits of FTW
0x118
DDSM_FTW[39:32]
Next 8 bits of FTW
0x119
DDSM_FTW[47:40]
8 MSBs of FTW
Unlike other NCO control registers, the FTW registers are not
applied to the NCO block immediately on writing the control
register. Instead, the FTW registers are applied (reset) on the
rising edge of DDSM_FTW_LOAD_REQ (Register 0x113, Bit 0).
After an update request, DDSM_FTW_LOAD_ACK
(Register 0x113, Bit 1) must indicate a high status to
acknowledge that the FTW is updated.
The DDSC_SEL_SIDEBAND bit Register 0x112, Bit 1 = 0b1)
is a convenience bit that controls whether the lower or upper
sideband of the modulated data is used, which is equivalent to
flipping the sign of the FTW.
INTERPOLATION
INTERPOLATION
NCO
1
0
–1
COS(ωn + θ)
θ
ω
π
SIN(ωn + θ)
I DATA
Q DATA
DDSM_FTW[47:0]
DDSM_SEL_SIDEBAND
OUT_I
OUT_Q
+
–
DDSM_NCO_PHASE_OFFSET
[15:0]
Figure 81. NCO Modulator Block Diagram, Main Datapath Modulus NCO
Mode (DDS)
Each of the main datapath 48-bit NCOs can also be used in a
dual modulus mode to create fractional frequencies beyond the
48-bit accuracy. The modulus mode is enabled by programming
the DDSM_MODULUS_EN bit in the DDSM_DATAPATH_
CFG register to 1 (Register 0x112, Bit 2 = 0b1).
The main datapath modulus NCOs are of a similar architecture to
the channel modulus NCOs, and the X (FTW), A, and B values are
calculated in a similar manner:
48
,
2
CARRIER
NCO CLK
A
X
f
M
B
fN

where:
X is the FTW, programmed in Register 0x114 to Register 0x119.
A is programmed in Register 0x12A to Register 0x12F.
B is programmed in Register 0x124 to Register 0x129.
For more details and examples, see the Channel Modulus NCO
Mode (Direct Digital Synthesis (DDS) Mode) section. The main
datapath NCOs operate at a higher clock rate (fNCO, CLK) than the
channel NCOs, and are addressed from a different set of SPI
registers.
NCO Reset
Resetting the main datapath NCOs can be useful when determ-
ining the start time and phase of an NCO. Each NCO can be
configured to reset in response to one of several events: a direct
request via SPI (Register 0x113, Bit 0), a change to one of the
FTW register values, or on the next SYSREF± rising edge. The
reset method is controlled by Register 0x113. See the detailed
description of Register 0x113 in Table 61 for more information.
Calibration NCO
In addition to the 48-bit NCO and the 31, 32-bit NCOs, there is
a 32-bit calibration NCO, which is also part of the main datapath
NCO block, shown in Figure 81. This NCO is separate from the
48-bit NCO, allowing a convenient method for generating a
calibration tone without the need to modify the configuration of
the main datapath. Similar to all other NCOs, this NCO can be
used in NCO only mode, or used to translate incoming data to a
new carrier frequency. Register 0x1E6, Bit 0 controls whether
the 32-bit calibration NCO is connected to the main datapath,
or whether the normal 48-bit main NCO is connected instead.
To use the 32-bit calibration NCO, first enable the calibration
NCO accumulator by setting Register 0x1E6, Bit 2 = 1. Then,
program the calibration NCO FTW in Register 0x1E2 to
Register 0x1E5 and update the FTW to take effect by toggling
Register 0x113, Bit 0 from 0 to 1. Select the calibration NCO to
be used instead of the main NCO by setting Register 0x1E6,
Bit 0 = 1. Similar to other NCOs, the calibration NCO can be
configured to operate in NCO only mode, which is enabled by
setting Register 0x1E6, Bit 1 = 1.
Set the amplitude of the tone can be set in Registers 0x148 and
Register 0x149. Refer to the NCO Only Mode section for more
details.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com