373 / 531 page ![]() DEBUG FUNCTION 7906 Group User’s Manual Rev.2.0 17-12 [Precautions for debug function] [Precautions for debug function] 1. The debug function cannot be evaluated by a debugger. Therefore, do not use a debugger when using the debug function. 2. When returning from an address matching detection interrupt routine, be sure to rewrite the saved contents of PG and PC to a certain return address, and then return there by using the RTI instruction. However, this is unnecessary processing when the software reset is performed within an address matching detection interrupt routine for program runaway detection, etc. 3. Be sure to set the start address of an instruction into the address compare register 0 or 1. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|