| Electronic Components Datasheet Search |
|
WM8903 Datasheet(PDF) 100 Page - Wolfson Microelectronics plc |
|
|
|||||||||||||||||||||||||||||
WM8903 Datasheet(HTML) 100 Page - Wolfson Microelectronics plc |
|
100 / 178 page ![]() WM8903 Production Data w PD, Rev 4.5, June 2012 100 USB CLOCKING MODE The clock division ratios with CLK_SYS_MODE = 01 or CLK_SYS_MODE = 10 allow compatibility with a 12MHz USB clock, at sample rates up to 48kHz. For example, with a 12MHz (USB) clock and 8kHz sample rate, the CLK_SYS to fs ratio is 1500. In this case, the required setting for CLK_SYS_RATE is 1001. Note that 44.1kHz and related sample rates are approximate when derived from a USB clock. For example, with a 12MHz MCLK and a division ratio of 272, the exact sample rate obtained is 44.118kHz rather than 44.1kHz. This 0.04% offset is inaudible and can be ignored. 48kHz and related sample rates are exact in all modes of operation, provided that MCLK itself is exact. ADC / DAC OPERATION AT 88.2K / 96K The WM8903 supports ADC or DAC operation at 88.2kHz and 96kHz sample rates. This section details specific conditions applicable to these operating modes. Note that simultaneous ADC and DAC operation at 88.2kHz or 96kHz is not possible. For DAC operation at 88.2kHz or 96kHz sample rates, the available clocking configurations are detailed in Table 64. Note that, for DAC operation at 88.2kHz or 96kHz sample rates, the ADCs must both be disabled (ADCL_ENA = 0 and ADCR_ENA = 0). Also, the DAC_OSR register should be set to 0. The CLK_SYS frequency is derived from MCLK. Note that the maximum MCLK frequency is defined in the “Signal Timing Requirements” section. SAMPLE RATE REGISTER CONFIGURATION CLK_SYS / fs RATIO 88.2kHz SAMPLE_RATE = 1001 CLK_SYS_RATE = 0001 CLK_SYS_MODE = 00 128 x fs CLK_SYS_MODE = 01 136 x fs CLK_SYS_MODE = 10 125 x fs 96kHz SAMPLE_RATE = 1010 CLK_SYS_RATE = 0001 CLK_SYS_MODE = 00 128 x fs CLK_SYS_MODE = 10 125 x fs Table 64 DAC Operation at 88.2kHz and 96kHz Sample Rates For ADC operation at 88.2kHz or 96kHz sample rates, the available clocking configurations are detailed in Table 65. Note that ADC operation at these sample rates is achieved by setting the SAMPLE_RATE field to half the required sample rate (eg. select 48kHz for 96kHz mode). In these modes, the BCLK_DIV field is set to select BCLK at double the normal rate. Note that, for ADC operation at 88.2kHz or 96kHz sample rates, the DACs must both be disabled (DACL_ENA = 0 and DACR_ENA = 0). The CLK_SYS frequency is derived from MCLK. Note that the maximum MCLK frequency is defined in the “Signal Timing Requirements” section. SAMPLE RATE REGISTER CONFIGURATION CLK_SYS / fs RATIO 88.2kHz SAMPLE_RATE = 0111 CLK_SYS_RATE = 0001 CLK_SYS_MODE = 00 BCLK_DIV = 00010 LRCLK_RATE = 040h 128 x fs 96kHz SAMPLE_RATE = 1000 CLK_SYS_RATE = 0001 CLK_SYS_MODE = 00 BCLK_DIV = 00010 LRCLK_RATE = 040h 128 x fs Table 65 ADC Operation at 88.2kHz and 96kHz Sample Rates |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |