| Electronic Components Datasheet Search |
|
TMP431 Datasheet(PDF) 23 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TMP431 Datasheet(HTML) 23 Page - Texas Instruments |
|
23 / 47 page ![]() TMP431, TMP432 www.ti.com SBOS441G – SEPTEMBER 2009 – REVISED DECEMBER 2015 Table 4. TMP432 Register Map (continued) POINTER ADDRESS BIT DESCRIPTIONS POWER-ON REGISTER RESET (HEX) DESCRIPTIONS READ WRITE D7 D6 D5 D4 D3 D2 D1 D0 Local temperature 29 NA 00 T3 T2 T1 T0 0 0 0 0 (low byte) 35 35 00 0 0 0 0 0 R2HIGH R1HIGH LHIGH High limit status 36 36 00 0 0 0 0 0 R2LOW R1LOW LLOW Low limit status 37 37 00 0 0 0 0 0 R2THERM R1THERM LTHERM Therm status Local temperature 3D 3D 00 LTH3 LTH2 LTH1 LTH0 0 0 0 0 high limit (low byte) Local temperature 3E 3E 00 LTL3 LTL2 LTL1 LTL0 0 0 0 0 low limit (low byte) Configuration 3F 3F 3C 0 0 REN2 REN LEN RC 0 0 register2 NA FC 00 X (3) X X X X X X X Software reset FD NA 32 0 0 1 1 0 0 1 0 TMP432 device ID FE NA 55 0 1 0 1 0 1 0 1 Manufacturer ID (3) X = Undefined. Writing any value to this register initiates a software reset; see Software Reset. 8.6.1 Pointer Register Figure 19 shows the internal register structure of the TMP43x. The 8-bit Pointer Register is used to address a given data register. The Pointer Register identifies which of the data registers should respond to a read or write command on the Two-Wire bus. This register is set with every write command. A write command must be issued to set the proper value in the Pointer Register before executing a read command. Table 3 describes the pointer address of the registers available in the TMP431. Table 4 describes the address of the registers available in the TMP432. The power-on reset (POR) value of the Pointer Register is 00h (0000 0000b). 8.6.2 Temperature Registers The TMP431 has four 8-bit registers that hold temperature measurement results. The TMP432 has six 8-bit registers that hold temperature measurement results. Both the local channel and the remote channel have a high byte register that contains the most significant bits (MSBs) of the temperature analog-to-digital converter (ADC) result and a low byte register that contains the least significant bits (LSBs) of the temperature ADC result. The local channel high byte address for the TMP43x is 00h; the local channel low byte address is 15h for the TMP431 and 29h for the TMP432. The remote channel high byte is at address 01h; the remote channel low byte address is 10h. For the TMP432, the second remote channel high byte address is 23h; the second remote channel low byte is 24h. These registers are read-only and are updated by the ADC each time a temperature measurement is completed. The TMP43x contain circuitry to assure that a low byte register read command returns data from the same ADC conversion as the immediately preceding high byte read command. This assurance remains valid only until another register is read. For proper operation, the high byte of a temperature register should be read first. The low byte register should be read in the next read command. The low byte register may be left unread if the LSBs are not needed. Alternatively, the temperature registers may be read as a 16-bit register by using a single two- byte read command from address 00h for the local channel result, or from address 01h for the remote channel result (23h for the second remote channel result). The high byte is output first, followed by the low byte. Both bytes of this read operation are from the same ADC conversion. The power-on reset value of both temperature registers is 00h. 8.6.3 Limit Registers The TMP43x have registers for setting comparator limits for both the local and remote measurement channels. These registers have read and write capability. The High and Low Limit Registers for both channels span two registers, as do the temperature registers. The local temperature high limit is set by writing the high byte to pointer address 0Bh and writing the low byte to pointer address 16h for the TMP431 and 3Dh for the TMP432, or by using a single two-byte write command (high byte first) to pointer address 0Bh. The local temperature high limit is obtained by reading the high byte from pointer address 05h and the low byte from pointer address 16h for the TMP4341 and 3Dh for the TMP432, or by using a two-byte read command from pointer address 05h. The power-on reset value of the local temperature high limit is 55h/00h (85°C in standard temperature mode; 21°C in extended temperature mode). Copyright © 2009–2015, Texas Instruments Incorporated Submit Documentation Feedback 23 Product Folder Links: TMP431 TMP432 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |