Back Button 32186 Datasheet HTML 309Page - Renesas Technology Corp 32186 Datasheet HTML 310Page - Renesas Technology Corp 32186 Datasheet HTML 311Page - Renesas Technology Corp 32186 Datasheet HTML 312Page - Renesas Technology Corp 32186 Datasheet HTML 313Page - Renesas Technology Corp 32186 Datasheet HTML 314Page - Renesas Technology Corp 32186 Datasheet HTML 315Page - Renesas Technology Corp 32186 Datasheet HTML 316Page - Renesas Technology Corp 32186 Datasheet HTML 317Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 313 / 1032 page
background image
MULTIJUNCTION TIMERS
10
10-17
32185/32186 Group Hardware Manual
Rev.1.10 REJ09B0235-0110 May 15, 07
b8
9
1011121314
b15
IEB3S
IEB2S
IEB1S
IEB0S
CKB2S
000
0000
0
The Clock Bus and Input/Output Event Bus Control Unit has the following registers:
• Clock Bus & Input Event Bus Control Register (CKIEBCR)
• Output Event Bus Control Register (OEBCR)
Clock Bus & Input Event Bus Control Register (CKIEBCR)
<Address: H’0080 0201>
<Upon exiting reset: H’00>
b
Bit Name
Function
R
W
8, 9
IEB3S
00: Select external input 3 (TIN3)
R
W
Input event bus 3 input select bit
01: Select external input 3 (TIN3)
10: Select output event bus 2
11: Select TIO7 output
10, 11
IEB2S
00: Select external input 0 (TIN0)
R
W
Input event bus 2 input select bit
01: Does not use input event bus 2
10: Select external input 4 (TIN4)
11: Select external input 4 (TIN4)
12
IEB1S
0: Select external input 5 (TIN5)
R
W
Input event bus 1 input select bit
1: Select TIO6 output
13
IEB0S
0: Select external input 6 (TIN6)
R
W
Input event bus 0 input select bit
1: Select TIO5 output
14
No function assigned. Fix to "0."
00
15
CKB2S
0: Select prescaler 2
R
W
Clock bus 2 input select bit
1: Select external clock 3 (TCLK3)
The CKIEBCR register is used to select the clock source (external input or prescaler) supplied to the clock bus
and the count enable/capture signal (external input or output event bus) supplied to the input event bus.
10.2 Common Units of Multijunction Timers



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com