| Electronic Components Datasheet Search |
|
AD9148BBCZ Datasheet(PDF) 43 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9148BBCZ Datasheet(HTML) 43 Page - Analog Devices |
|
43 / 73 page ![]() Preliminary Technical Data AD9148 Rev. PrA | Page 43 of 73 No Synchronization In this mode, Bit 7 in Register 0x10 is set to 0, the pipeline delay in the signal processing is not controlled, and the read pointer of the FIFO is never reset. However, to assure that the FIFO can operate safely and there is no concurrent access to FIFO from the write and read pointer to the same address, it is important to ensure that the phase offset between the two pointers is greater than 2. In consequence, the only FIFO reset that can be used safely is the data rate synchronization, Bit 6 of Register 0x10 set to 0, where the FIFO is reset with a fixed offset of 4 between the write and read pointers. As there is no SYNC signal, the reset of the FIFO write pointer can only be done by a FRAME signal or an SPI command. FIFO Reset Commands Depending on the configuration of the system, the FIFO reset could be done manually or periodically for a multichip system. The AD9148 provides two ways to resetting the FIFO pointers: SPI interface or periodic reset using the FRAME signal. The SPI also gives access to each FIFO phase offset in Bits [2:0] of the corresponding FIFO status/control registers, Address 0x17 and Address 0x19. The value in these three bits corresponds either to the offset between the write and read pointer in the data rate synchronization or to the absolute address of the FIFO write pointer in the FIFO rate synchronization. SPI Command for Manual Reset If a manual reset is acceptable, the FIFO pointer addresses can be reset using the SPI interface. To initialize the FIFO data level through the SPI, Bit 3 of Register 0x17 (FIFO Port A) or Bit 3 of Register 0x19 (FIFO Port B) should be toggled from 0 to 1 and back. When the write to the register is complete, the corresponding FIFO data level is initialized. The recommended procedure for a SPI FIFO data level initialization is: 1. Request FIFO Port A or FIFO Port B level reset by setting Bit 3 in Register 0x17 or Bit 3 in Register 0x19 to Logic 1. The FIFO phase offset, Bits [2:0] in Register 0x17 or Bits [2:0] in Register 0x19 should also be written at the same time to set the desired value of offset between the FIFO write and read pointers. 2. Verify the part acknowledges the request by ensuring Bit 4 in Register 0x17 or Bit 4 in Register 0x19 is set to Logic 1. 3. Remove the request by resetting Bit 3, Register 0x17 or Bit 3, Register 0x19 to 0. 4. The FIFO SPI aligned flag in the Event Flag 0 register, Bit 2 in Register 0x06, is set when the reset of the write pointer has been realized. Bit 4 in Register 0x17 or Bit 4 in Register 0x19 is reset to 0 to indicate which FIFO has generated this flag. Note that the SPI writes to Register 0x17 or Register 0x19 should be done while maintaining a constant value in the FIFO phase offset bits. FIFO Reset Using FRAME Signal The FIFO pointers can also be reset using the FRAME signals. If only one DCI is used, only the FRAMEA signal is used for the FIFO reset. This mode is enabled by setting Bit 6 in Register 0x10. As discussed in the FIFO Synchronization Modes section, the FRAME input is used to initialize the FIFO data level value. When the FRAME signal is asserted high for at least the time interval needed to load the complete data to the four DACs, the write pointer is reset depending on the mode of synchronization chosen: • Data rate synchronization (default), Bit 6 of Register 0x10, is set to 0. Write pointer reset to FIFO offset phase when read pointer reaches 0. • FIFO rate synchronization, Bit 6 of Register 0x10, is set to 1. Write pointer reset to FIFO start level on rising edge of FRAME signal. MONITORING THE FIFO STATUS The FIFO initialization and status can be read from Register 0x17. This register provides information about the FIFO initialization method and whether the initialization was successful. The MSB of Register 0x17 is a FIFO warning flag that can optionally trigger a device IRQ. This flag is an indication that the FIFO is close to emptying (FIFO level is 1) or overflowing (FIFO level is 7). This is an indication that the data may soon be corrupted, and action should be taken. The FIFO data level can be read from Register 0x18 at any time. The SPI reported FIFO data level is denoted as a 7-bit thermometer code of the write counter state relative to the absolute read counter being 0. The optimum FIFO data level of four is, therefore, reported as a value of 00001111 in the status register. Note that, depending on the timing relationship between DCI and the main DACCLK, the FIFO level value can be off by a ±1 count. Therefore, it is important to keep the difference between the read and write points to at least two. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |