Back Button AD9148BBCZ Datasheet HTML 46Page - Analog Devices AD9148BBCZ Datasheet HTML 47Page - Analog Devices AD9148BBCZ Datasheet HTML 48Page - Analog Devices AD9148BBCZ Datasheet HTML 49Page - Analog Devices AD9148BBCZ Datasheet HTML 50Page - Analog Devices AD9148BBCZ Datasheet HTML 51Page - Analog Devices AD9148BBCZ Datasheet HTML 52Page - Analog Devices AD9148BBCZ Datasheet HTML 53Page - Analog Devices AD9148BBCZ Datasheet HTML 54Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 50 / 73 page
background image
AD9148
Preliminary Technical Data
Rev. PrA | Page 50 of 73
DIGITAL DATA PATH
The block diagram in Figure 59 shows the functionality of the
complex digital data path. The digital processing includes a
premodulation block, a programmable complex filter, three
half-band interpolation filters with built-in coarse modulation,
a quadrature modulator with a fine resolution NCO as well as
phase, gain, and offset adjustment blocks.
HB2
PREMOD
fS/2
HB1
HB3
DIGITAL
PHASE/GAIN/
OFFSET ADJ
PROG
SINC–1
FILTER
Figure 59. Block Diagram of Digital Data Path
There are two complex digital data paths that feed the four DACs.
Each digital data path accepts I and Q data streams and processes
them as a quadrature data stream, resulting in two quadrature
data streams. All of the signal processing blocks can be used
when the input data stream is represented as complex data.
The data path can be used to process an input data stream
representing four independent real data streams as well; however,
the functionality is somewhat restricted. The premodulation
block can be used, as well as any of the nonshifted interpolation
filter modes.
PREMODULATION
The half-band interpolation filters have selectable pass bands
that allow the center frequencies to be moved in increments of
½ of their input data rate. The premodulation block provides a
digital upconversion of the incoming waveform by ½ of the
incoming data rate, fDATA. Functionally, the premodulation
multiplies the incoming data samples alternatively by +1 and −1.
This can be used to frequency shift baseband input data to the
center of the interpolation filters pass band.
PROGRAMMABLE INVERSE SINC FILTER
The AD9148 provides a programmable inverse sinc filter to
compensate the DAC roll-off over frequency. As this filter is
implemented before the interpolation filter, its coefficients need
to be changed depending on the interpolation rate and DAC
output center frequency.
Filter Structure
The programmable inverse sinc filter is a 9-tap complex FIR
filter using complex conjugate coefficients. The z-transfer
function is:
()
8
0
7
1
6
2
5
3
4
4
3
3
2
2
1
1
0
−
−
−
−
−
−
−
−
×
+
×
+
×
+
×
+
×
+
×
+
×
+
×
+
=
×
+
=
×
+
×
+
=
z
c
z
c
z
c
z
c
z
c
z
c
z
c
z
c
c
H
j
H
x
j
x
y
j
y
z
H
Q
I
Q
I
Q
I
where:
xI and xQ are the in-phase (real) and quadrature (imaginary)
filter input, respectively.
yI and yQ are the in-phase (real) and quadrature (imaginary)
filter output, respectively.
HI and HQ are the in-phase (real) and quadrature (imaginary)
filter coefficients, respectively.
c0, c1, c2, c3, and c4 are the complex filter coefficient, and cX their
complex conjugate.
The filter coefficients need to be calculated and programmed
into the AD9148 registers to perform the operation desired.
Filter Implementation
To perform the complex filtering of the complex input, the filter
is divided in four filters working in parallel, two sets of HI and
two sets of HQ (see Figure 60).
(
) (
)
()
Q
I
I
Q
Q
Q
I
I
Q
i
Q
I
Q
I
x
H
x
H
j
x
H
x
H
x
j
x
H
j
H
y
j
y
×
+
×
⋅
+
×
−
×
=
×
+
⋅
×
+
=
×
+
XI
HI
HQ
YI
YQ
XQ
HI
HQ
+
–
+
+
Figure 60. Complex Filter Implementation
The coefficients for the filter are stored in SPI Register 0x20 to
Register 0x27 in twos-complement format. They have variable
length, 3 bits to 10 bits.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com