39 / 77 page ![]() C165 Data Sheet 35 V2.0, 2000-12 RSTIN active current4) IRSTL 6) -100 – µA VIN = VIL READY/RD/WR inact. current7) IRWH 5) –- 40 µA VOUT = 2.4 V READY/RD/WR active current7) IRWL 6) -500 – µA VOUT = VOLmax ALE inactive current7) IALEL 5) –40 µA VOUT = VOLmax ALE active current7) IALEH 6) 500 – µA VOUT = 2.4 V Port 6 inactive current7) IP6H 5) –- 40 µA VOUT = 2.4 V Port 6 active current7) IP6L 6) -500 – µA VOUT = VOL1max PORT0 configuration current8) IP0H 5) –- 10 µA VIN = VIHmin IP0L 6) -100 – µA VIN = VILmax XTAL1 input current IIL CC – ± 20 µA0 V < V IN < VDD Pin capacitance9) (digital inputs/outputs) CIO CC – 10 pF f = 1 MHz TA = 25 °C 1) Keeping signal levels within the levels specified in this table, ensures operation without overload conditions. For signal levels outside these specifications also refer to the specification of the overload current IOV. 2) Valid in bidirectional reset mode only. 3) This specification is not valid for outputs which are switched to open drain mode. In this case the respective output will float and the voltage results from the external circuitry. 4) These parameters describe the RSTIN pullup, which equals a resistance of ca. 50 to 250 k Ω. 5) The maximum current may be drawn while the respective signal line remains inactive. 6) The minimum current must be drawn in order to drive the respective signal line active. 7) This specification is valid during Reset and during Hold-mode or Adapt-mode. During Hold-mode Port 6 pins are only affected, if they are used (configured) for CS output and the open drain function is not enabled. The READY-pullup is always active, except for Powerdown mode. 8) This specification is valid during Reset and during Adapt-mode. 9) Not 100% tested, guaranteed by design and characterization. DC Characteristics (Standard Supply Voltage Range) (cont’d) (Operating Conditions apply)1) Parameter Symbol Limit Values Unit Test Condition min. max. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |