| Electronic Components Datasheet Search |
|
PC87591L Datasheet(PDF) 243 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
PC87591L Datasheet(HTML) 243 Page - National Semiconductor (TI) |
|
243 / 437 page ![]() Embedded Controller Modules (Continued) Revision 1.07 243 www.national.com When transitioning from SuperI/O Enabled PMC Enabled state, there may be a transition period in which the core domain clock is still toggling according to the setting in SuperI/O Enabled PMC Enabled state. This occurs until software method 1 is performed by the interrupt handler of the SuperI/O Disabled event. Transition to SuperI/O Enabled PMC Disabled State ● OSCCLK defaults to 96 MHz ● The host domain clock is enabled and starts toggling as soon as the frequency multiplier has stabilized ● The core domain clock is disabled (low) Transition to SuperI/O Enabled PMC Enabled State ● When transitioning from SuperI/O Enabled PMC Disabled state: — OSCCLK defaults to 96 MHz — The pre-scaler is set according to HFCGP ● When transitioning from PMC Enabled SuperI/O Disabled state: — Software sets OSCCLK and the pre-scaler by the LOAD96 or FAST96 command (software method 2) ● The host domain clock is enabled and starts toggling as soon as the frequency multiplier has stabilized ● The core domain clock is enabled and starts toggling as soon as the frequency multiplier has stabilized When transitioning from PMC Enabled SuperI/O Disabled state, there may be a transition period in which the core domain clock is still toggling according to the setting in PMC Enabled SuperI/O Disabled state. This occurs until software method 2 is performed by the interrupt handler of the SuperI/O Enabled event. During this transition period, the host domain clock is still disabled. 4.18.6 48 MHz Clock Monitor While in one of the SuperI/O Enabled states, a WATCHDOG reset or Debugger Interface reset does not interfere with the operation of the SuperI/O. Thus, if the 48 MHz clock is correctly toggling, it is not interfered with. Toggling is monitored by the 48 MHz clock monitor. If a violation is detected, the 48 MHz monitor error flag is set and the HFCG goes through a com- plete reset, after which it is put into PMC Enabled SuperI/O Disabled state, ignoring the host domain enable signal. The 48 MHz clock monitor is initiated when a WATCHDOG reset or Debugger Interface reset occurs while the HFCG is in a SuperI/O Enabled state. The monitor checks that the host domain clock frequency is in the range of 48 MHz ±1%. If the host domain clock frequency is in the correct range, the HFCG continues generating the 96 MHz OSCCLK, but the programmable pre-scaler is set to a default of divide by 24. The HFCG is in SuperI/O Enabled PMC Enabled state. The core reset routine is responsible for switching to SuperI/O Enabled PMC Enabled state and/or communicating the failure to the host software. 4.18.7 HFCG Registers For a summary of the abbreviations used for Register Type, see “Register Abbreviations and Access” on page 34. HFCG Register Map Mnemonic Register Name Type HFCGCTRL1 HFCG Control 1 Varies per bit HFCGML M Low Byte Value R/W HFCGMH M High Byte Value R/W HFCGN N Value R/W HFCGIL I Low Byte Value R/W HFCGIH I High Byte Value R/W HFCGP HFCG Pre-Scaler R/W HFCGCTRL2 HFCG Control 2 Varies per bit |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |